29
(3) Monitor display
●
Start:
Press the MODE and HUMIDITY SELECTION buttons together 5 times when the power is off.
Press the POWER button within 2 seconds.
●
Mode selection: Use the time switch to change through display modes (0 to 3).
(4) Demonstration program
●
Start:
Hold the MODE and HUMIDITY SELECTION buttons together and press the POWER button. The
demonstration starts after 3 seconds.
●
Functions:
1
Blower locked at rank 3.
2
Compressor and valve stopped.
3
LCD and LED light at random.
●
To end:
Unplug
30% ~ 80% 1% increments
0
°
C ~ 39
°
C
0 ~ 6
0
°
C ~ 12
°
C
Humidity indication
Fan rank indication
3
2
1
0
Tube temperature
data indication
Room temperature
indication
Example: Room temperature 21
°
C
Display mode
21
°
C
(2) Deactivating 3-minute restart prevent lock
●
Start:
Press the MODE and HUMIDITY SELECTION buttons (Auto buttons for the E16S) together 3
times when the power is off. Press the POWER button within 2 seconds.
●
Functions:
1
Deactivates 3-minute restart prevention lock
2
Activates compressor
3
Operating mode: Low Temp
4
Operates blower on HIGH
●
To end:
Turn power off. Valve functions for 3 seconds.
E16SX
E16SX