* Rank 1=Lb, Rank 2=La, Rank 3=Mi, Rank 4=Hi, Rank 5=HH, Rank 6=SH
4
Mildew Guard mode
(a) Alternately activates/deactivates compressor or blower according to current humidity/time. (Fan rank is as shown in
2
)
(b) Operates dehumidifier when Mildew guard mode is activated or every 24 hours after activation.
(c) Dehumidifier is deactivated when the following parameters are breached. (Compressor and blower stop)
• 2 hours of below 40% elapses and below 35% is detected.
• 4 hours of below 50% elapses and below 45% is detected.
*
However, if the humidity rises above the given levels for more than 3 minutes, the accumulated time returns to zero.
(d) If the humidity rises to 75% after deactivation, the dehumidifier automatically operates until the humidity is brought down to 65%.
(e) If 24 hours elapse from the time the unit was turned on, all accumulated time counts for all humidity levels are reset.
2HR
2HR
4HR
4HR
45%
Elapsed time
35%
Elapsed time
Humidity level
Compressor
Blower
Mildew
Guard
ON
Below 45%
time count
start
Below 35%
time count
start
Below 35%
time count
stop
Dehumidifier
activated
Below 35%
time count
start
Dehumidifier
deactivated
Dehumidifier
deactivated
Dehumidifier
deactivated
Accumulated
time counts
reset
65%
45%
40%
35%
24HR
75%
ON
OFF
Below
45%
Below
35%
3 minutes
above 40%
elapse
Limit
75%
Limit
recovered 65%
14
<Operation Control>
1
Humidity set operation
(a) Compressor and blower fan operation will switch by current humidity and set temperature.
2
Specifications shared at all operation modes
(a) Dehumidifying will not start for about 2 seconds when turning the operation power on with the swing stopped. (However, humidifying
will begin immediately when pressing the swing louvre switch within 2 seconds of turning the power on.)
(b) The compressor and blower fan will operate for about 7 minutes after turning on the operation switch or activating the compressor,
regardless of humidity or temperature levels.
3
Low, Low Temp, Mildew Guard, Air Purifier, Laundry
Compressor
ON
Rank 1
Rank 1
Rank 2
Rank 2
Rank 5
Rank 5
Stopped
Stopped
Stopped
27
°
C
34
°
C
29
°
C
36
°
C
ON
OFF
Current humidity
– Set humidity
Decline in
current
humidity
+3%
–1%
+5%
+1%
Rise in current
humidity
Blower fan rank
Mildew Guard E16SX only
Low
Air Purifier
E16S only
Low Temp
Laundry
E16S only
Laundry
E16SX only
ON
ON
ON
ON
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
ON
ON
Compressor
OFF
ON
Rank 1
Rank 1
Rank 1
Rank 1
Rank 1
Rank 1
Rank 1
Rank 1
Rank 6
Rank 2
Rank 2
Rank 2
Rank 2
Rank 5
Rank 5
Rank 5
E16S
E16S
E16SX
E16SX
E16SX
E16SX
E16SX
E16S
E16S
E16S
Rank 5
Rank 5
Rank 5
Rank 5
Rank 2
Rank 2
Rank 2
Rank 2
Rank 2
Rank 3
Rank 4
Rank 4
Rank 4
Rank 4
Rank 3
Rank 6
14
°
C
27
°
C
34
°
C
16
°
C
29
°
C
Blower fan rank
36
°
C
E16SX
E16SX
E16SX
E16S
E16SX
Summary of Contents for MJ-E16S-S1
Page 21: ...21 6 4 Board Diagrams Componet Side Power supply board diagram Control board E16S E16SX ...
Page 22: ...22 6 5 General Block Diagram E16S ...
Page 23: ...23 ...
Page 24: ...24 E16SX ...
Page 25: ...25 ...
Page 40: ...40 Parts Catalog Model MJ E16S SX S1 Exploded View Electrical Parts 3 b c 5 4 2 1 6 d 9 8 7 a ...