MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-275
STEP 2. Check the fuel temperature sensor.
(1) Disconnect the fuel temperature sensor connector D-17
(2) Measure the resistance between terminal 1 and 3 of the fuel
temperature sensor.
Standard value:
0.5
−
12.0 k
Ω
Q: Is the resistance at the standard value?
YES :
Go to Step 3.
NO :
Replace the fuel temperature sensor. Then go to Step
5.
STEP 3. Check connector D-17 at the fuel temperature
sensor and connector C-62 at ECM <M/T> or connector C-
55 at PCM <A/T> for damage.
Q: Is the connector in good condition?
YES :
Go to Step 4.
NO :
Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then go to Step 5.
AK101374
1 2 3
4 5
AB
1 2 3
4 5
FUEL TEMPERATURE SENSOR
SIDE CONNECTOR
AK000734AC
CONNECTOR:D-17
AK000225
CONNECTORS : C-62<M/T>, C-55<A/T>
C-55
PCM<A/T>
ECM<M/T>
AP
C-62