MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-145
STEP 5. Check the right bank heated oxygen sensor
(front).
(1) Disconnect the right bank heated oxygen sensor (front)
connector B-27 and connect test harness special tool,
MD998464 to the connector on the right bank heated
oxygen sensor (front) side.
(2) Warm up the engine until engine coolant 80
°
C (176
°
F) or
higher.
CAUTION
Be very careful when connecting the jumper wires; incor-
rect connection can damage the right bank heated oxygen
sensor (front).
(3) Use the jumper wires to connect terminal 1 (red clip) to the
positive battery terminal and terminal 3 (blue clip) to the
negative battery terminal.
(4) Connect a digital volt meter between terminal 2 (black clip)
and terminal 4 (white clip).
(5) While repeatedly revving the engine, measure the right
bank heated oxygen sensor (front) output voltage.
Standard value: 0.6
−
1.0 V
Q: Is the voltage at the standard value?
YES :
Go to Step 6.
NO :
Replace the right bank heated oxygen sensor (front).
Then go to Step 14.
STEP 6. Check connector B-48 at injector intermediate
connector for damage.
Q: Is the connector in good condition?
YES :
Go to Step 7.
NO :
Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then go to Step 14.
ACX02481
ACX02481AH
RIGHT BANK
HEATED OXYGEN
SENSOR (FRONT)
AK103507
CONNECTOR: B-27
AK103507AB
AKX01625AC
BLUE
RED
BLACK
JUMPER
WIRES
WHITE
MD998464
AK000209AC
CONNECTOR:B-48