![Mitsubishi MOTORS Eclipse Manual Download Page 195](http://html1.mh-extra.com/html/mitsubishi-motors/eclipse/eclipse_manual_1812184195.webp)
MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-195
.
CIRCUIT OPERATION
•
A voltage corresponding to the oxygen concen-
tration in the exhaust gas is sent to the ECM (ter-
minal 71) <M/T> or PCM (terminal 71) <A/T>
from the output terminal (terminal 4) of the left
bank heated oxygen sensor (front).
•
Terminal 2 of the left bank heated oxygen sensor
(front) is grounded with ECM (terminal 49) <M/T>
or PCM (terminal 57) <A/T>.
.
TECHNICAL DESCRIPTION
•
The left bank heated oxygen sensor (front)
detects the concentration of oxygen in the
exhaust gas; it converts that data to voltage, and
sends it to the ECM <M/T> or PCM <A/T>.
•
When the left bank heated oxygen sensor (front)
begins to deteriorate, the heated oxygen sensor
signal response deteriorates also.
•
The ECM <M/T> or PCM <A/T> varies the air/fuel
mixture to make it leaner and richer, and checks
the response speed of the left bank heated oxy-
gen sensor (front). In addition, the ECM <M/T> or
PCM <A/T> also checks for an open circuit in the
left bank heated oxygen sensor (front) output
line.
.
DTC SET CONDITIONS
Check Conditions
•
3 minutes or more have passed since the starting
sequence was completed.
•
Left bank heated oxygen sensor (front) signal
voltage has continued to be 0.2 volt or lower.
•
Engine coolant temperature is higher than 76
°
C
(169
°
F).
•
Engine speed is higher than 1,200 r/min.
•
Volumetric efficiency is higher than 25 percent.
•
Volume air flow sensor output frequency is 75 Hz
or more.
•
At least 20 seconds have passed since fuel shut
off control was canceled.
•
After the ignition switch is turned ON, the
changes in the output voltage of the left bank
heated oxygen sensor (front) is lower than 0.078
volt.
•
Monitoring time: 10 seconds.
Judgement Criteria
•
Making the air/fuel ratio 15 percent for 10 sec-
onds richer does not result in raising the heated
oxygen sensor (front) output voltage beyond 0.15
volt.
•
The ECM <M/T> or PCM <A/T> monitors for this
condition once during the drive cycle.
.
TROUBLESHOOTING HINTS (The most likely
causes for this code to be set are: )
•
Left bank heated oxygen sensor (front) failed.
•
Short circuit in left bank heated oxygen sensor
(front) output line.
•
ECM failed. <M/T>
•
PCM failed. <A/T>
DIAGNOSIS
Required Special Tools:
•
MB991502: Scan Tool (MUT-II)
•
MD998464: Test Harness
AK000225
CONNECTORS : C-58, C-62<M/T>,
C-55, C-59<A/T>
C-55
C-58
PCM<A/T>
ECM<M/T>
AK
C-59
C-62