MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-162
STEP 8. Check the continuity at right bank heated oxygen
sensor (rear) harness side connector B-28.
(1) Disconnect the connector B-28 and measure at the harness
side.
(2) Check for the continuity between terminal 2 and ground.
•
Should be less than 2 ohm.
Q: Is the continuity normal?
YES :
Go to Step 11.
NO :
Go to Step 9.
STEP 9. Check connector C-58 at ECM <M/T> or connector
C-55 at PCM <A/T> for damage.
Q: Is the connector in good condition?
YES :
Go to Step 10.
NO :
Repair or replace it. Refer to GROUP 00E, Harness
Connector Inspection
. Then go to Step 15.
AK000243AB
B-28 HARNESS
SIDE CONNECTOR
2 1
4 3
AK000225
CONNECTOR : C-58<M/T>, C-55<A/T>
C-55
C-58
PCM<A/T>
ECM<M/T>
AI