MULTIPORT FUEL INJECTION (MFI) DIAGNOSIS
TSB Revision
MULTIPORT FUEL INJECTION (MFI) <3.0L>
13B-445
STEP16. Pressure test for clogging in the evaporator line
from hose I to hose P.
(1) Disconnect hose I from the evaporative emission canister
side, and unplug the hose I.
(2) On the EVAP pressure pump, set the pressure/hold valve to
OPEN, and set the vent valve to CLOSED. Turn the pump
timer to ON. You can reset the timer as required. (These
settings are listed under "Leak Test" in the pump
instructions.)
(3) Air should pass through hose G.
Q: Is air blown from hose I?
YES :
Connect the hose I. Then go to Step 17.
NO :
Go to Step 21.
STEP17. Pressure test for clogging in the evaporator line
from hose F to hose H.
(1) Unplug hose G.
(2) On the EVAP pressure pump, set the pressure/hold valve to
OPEN, and set the vent valve to CLOSED. Turn the pump
timer to ON. You can reset the timer as required. (These
settings are listed under "Leak Test" in the pump
instructions.)
(3) Air should pass through hose G.
Q: Is air blown from hose G?
YES :
Connect the hose G. Then go to Step 18.
NO :
Go to Step 19.
AC002072 AB
HOSE I
OPEN
OPEN
CLOSED
CLOSED
Pressure
Hold
Vent
ACX01806
OPEN
OPEN
CLOSED
CLOSED
Pressure
Hold
Vent
ACX01806
AC002029
HOSE E
AC