![Mitsubishi Heavy Industries WF-RAC Technical Manual Download Page 16](http://html1.mh-extra.com/html/mitsubishi-heavy-industries/wf-rac/wf-rac_technical-manual_1812151016.webp)
'21 • SRK-T-324
-
14
-
EN-8
2. Connecting this product with the indoor unit
Connect the indoor unit connection cable to the indoor control printed-
circuit board.
・
For the connection of the indoor unit, refer to the “description for
connecting the interface kit” in the installation manual of the indoor
unit.
・
Connect the connector of the indoor unit connection cable to the
terminal (CNS) on the indoor control board by installing the cable
along the wiring route from below.
・
Securely connect the connector of the indoor connection cable to
the CNS terminal on the indoor control board.
● About the handling of the connection cable
If the connection cable is too long, the redundant cable section
should be stored loosely in a space on the back of the indoor unit.
4. WIRING CONNECTION
5. PRINTED-CIRCUIT BOARD COMPONENT LAYOUT
To CNS
Printed-circuit
board
Connector
Connection cable
CNS
Connection cable
Reset button (SW3)
Power button (SW1)
Set button (SW2)
Indoor unit
connecting terminal (CN1)
Front
Back
-
3
-