Automatic operation is impossible
(Remote control function)
Temperature setting button is not working
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
Function
Function
setting
setting
Mode button is not working
On/Off button is not working
Fan speed button is not working
Louver button is not working
Timer button is not working
Heating preparation indication should not be indicated.
Remote thermistor is not working.
Remote thermistor is working.
Remote thermistor is working, and to be set for pro3.0
°
C increase in temperature.
Remote thermistor is working, and to be set for pro2.0
°
C increase in temperature.
Remote thermistor is working, and to be set for pro1.0
°
C increase in temperature.
Remote thermistor is working, and to be set for producing -1.0
°
C increase in temperature.
Remote thermistor is working, and to be set for producing -2.0
°
C increase in temperature.
Remote thermistor is working, and to be set for producing -3.0
°
C increase in temperature.
Airflow of fan becomes the three speed of - - .
Airflow of fan becomes the two speed of - .
Airflow of fan becomes the two speed of - .
Airflow of fan is fixed at one speed.
When you use at 50Hz area
When you use at 60Hz area
If you change the range of set temperature, the indication of set temperature will vary following the control.
If you change the range of set temperature, the indication of set temperature will not vary following the control, and
keep the set temperature.
In normal working indication, indoor unit temperature is indicated instead of airflow.
(Only the master remote control can be indicated. )
If you change the remote control function "14 ",
you must change the indoor function "04 " accordingly.
You can select the louver stop position in the four.
The louver can stop at any position.
Temperature indication is by degree C
Temperature indication is by degree F
In case of Single split series, by connecting ventilation device to CNT of the indoor printed circuit board, the operation of
ventilation device is linked with the operation of indoor unit.
In case of Single split series, by connecting ventilation device to CNT of the indoor printed circuit board, you can operate/
stop the ventilation device independently by (VENT) button.
If you input signal into CNT of the indoor printed circuit board from external, the indoor unit will be operated
independently according to the input from external.
If you input into CNT of the indoor printed circuit board from external, all units which connect to the same remote
control are operated according to the input from external.
Start
: While indoor unit do not operate, press “
” (SET) and “
” (MODE) button for 3 seconds at the same time.
Finalizea
: Press “
” (SET) button.
Reset
: Press “
” (RESET) button.
Select
: Press
button.
End
: Press
button.
It is possible to finish above setting on the way, and unfinished change of setting is unavailable.
“ ” : Initial settings
“ ” : Automatic criterion
“ ” : The SRK model cannot set the items described in
in the function.
(1) The initial function setting for typical using is performed automatically for a remote control unit and an
indoor unit by the outdoor unit connected, when remote control and inside unit are connected.
As long as they are used in a typical manner, there wiil be no need to change the initial settings.
If you would like to change the initial setting marked “ ”, set your desired setting as for the selected item.
The procedure of functional setting is shown as the following diagram.
As for detail of setting, refer to the installation manual of remote control.
(2) Flow of function setting
(3)
Clearing the function setting
Pressing
(CHECK) +
(TIMER) +
(MODE) buttons simultaneously reverts the function setting data to
the data which are set at the shipping from factory.
1
Remote control unit functions ( FUNCTION
)
9. Setting functions using the wired remote control