For Home Owners
- 10 -
Comfort setting heating
Comfort setting heating
General
The indoor temperature depends on several factors.
Ŷ 6XQOLJKWDQGKHDWHPLVVLRQVIURPSHRSOHDQGKRXVHKROG
PDFKLQHVDUHQRUPDOO\VXI¿FLHQWWRNHHSWKHKRXVHZDUP
during the warmer parts of the year.
Ŷ :KHQLWJHWVFROGHURXWVLGHWKHKHDWLQJV\VWHPPXVWEH
started. The colder it is outside, the warmer radiators and
XQGHUÀRRUKHDWLQJV\VWHPVPXVWEH
Controlling heat production
Normally, the heat pump heats the water (heating medium) to
the temperature required at a certain outdoor temperature. This
occurs automatically on the basis of the collected temperature
values from the outdoor sensor and sensors on the lines to the
UDGLDWRUV 6XSSO\ ZDWHU VHQVRUV ([WUD DFFHVVRULHV VXFK DV
URRPVHQVRUVFDQLQÀXHQFHWKHWHPSHUDWXUH
,QRUGHUWRRSHUDWHWKHV\VWHPSURSHUO\WKHFRUUHFWVHWWLQJV
PXVWEHPDGHRQWKHKHDWSXPS¿UVWVHHWKHVHFWLRQ³'HIDXOW
Heating curve setting”.
The outdoor sensor (mounted on an exterior wall of the house)
senses variations in the outdoor temperature early on, sends the
information to the heat pump control computer and heating
RSHUDWLRQLVVWDUWHG,WGRHVQRWKDYHWREHFROGLQVLGHWKHKRXVH
before the control system is activated. As soon as the
temperature drops outside, the temperature of the water to the
radiators (supply temp.) inside the house is increased
automatically.
The heat pumps flow temperature (Menu 2.0) will hover
DURXQGWKHWKHRUHWLFDOUHTXLUHGYDOXHZKLFKLVLQEUDFNHWVRQ
the display.
Temperature of the heating system
The temperature of the heating system in relation to the
outdoor temperature can be determined by you by selecting a
KHDWFXUYHDQGE\XVLQJWKH³2IIVHWKHDWLQJFXUYH´NQRERQWKH
heat pump’s front panel.
Operating status
The “Operating mode” button is used to set the required
operating mode.
The change does not need to be confirmed with the
enter button.
The current operating mode is shown on the front panel display
when the button is pressed and the mode changes when you
continue to press the button.
The display returns to the normal display mode once the enter
button is pressed.
7KHHOHFWULFKHDWHULVRQO\XVHGIRUDQWLIUHH]HLILWLVGHDFWLYDWHG
in the menu system for all operating modes.
7KHUHDUHGLIIHUHQWRSHUDWLQJPRGHVWRFKRRVH
1. “Auto”
HM270V automatically selects the operating mode by
WDNLQJWKHRXWGRRUWHPSHUDWXUHLQWRDFFRXQW7KLVPHDQV
that the operating mode switches between “Heating” and
“Hot water”.
The circulation pump is permitted to operate when there is
a need.
2. “AutoC”*
HM270V selects operating mode automatically (cooling
can also be selected now) by the outdoor temperature. This
means that the operating mode switches between
“Heating”, “Cooling” and “Hot water”.
The circulation pump is permitted to operate when there is
a need.
3. Heating
Only heating and hot water mode.
The circulation pump is in operation the entire time.
(OHFWLUFKHDWHULVHQHUJL]HGLIQHFHVVDU\
4. Cooling*
Heat pump is used for cooling only if electric heater use is
allowed. Otherwise, it is used for both cooling and hot water.
The circulation pump is in operation the entire time.
5. Hot water
Only hot water is produced.
Only the compressor is operational.
6. Add. Heat only
Heat pump is not operational. The function is activated/
deactivated by pressing in the “operating mode button” for
7 seconds.
* To use the cooling functions, the system must be designed to
withstand low temperatures and cooling must be activated in
Menu 9.3.3.
Changing the room temperature manually
,I\RXZDQWWRWHPSRUDULO\RUSHUPDQHQWO\LQFUHDVHRUORZHU
WKHLQGRRUWHPSHUDWXUHWXUQWKH³2IIVHWKHDWLQJFXUYH´NQRE
FORFNZLVH WR LQFUHDVH RU DQWLFORFNZLVH WR ORZHU 2QH OLQH
approximately represents 1 degree change in room temperature.
NOTE
An increase in the room temperature may be inhibited
E\WKHUDGLDWRURUXQGHUÀRRUKHDWLQJWKHUPRVWDWVLIVR
these must be set at 0.
Summary of Contents for FDCW100VNX
Page 7: ...For Home Owners 6 For Home Owners ...
Page 20: ...Installation 19 Installation ...
Page 42: ...Control 41 Control ...
Page 66: ...System description 65 System description ...
Page 81: ...Service 80 Service ...
Page 148: ...Components 147 Components ...
Page 155: ...Technical data 154 Technical data ...
Page 156: ...Technical data Electrical circuit diagram 155 Electrical circuit diagram HM270V ...
Page 157: ...Technical data Electrical circuit diagram 156 ...
Page 158: ...Technical data Electrical circuit diagram 157 ...
Page 159: ...Technical data Electrical circuit diagram 158 ...
Page 160: ...Technical data Electrical circuit diagram 159 ...