![Mitsubishi Electric VS-45605 Technical Training Manual Download Page 8](http://html.mh-extra.com/html/mitsubishi-electric/vs-45605/vs-45605_technical-training-manual_240110008.webp)
Page 1-5
feature. If the duration exceeds 10 seconds, pressing
"PIP/POP" terminates the PIP mode.
In the Single PIP Insert mode, the "Size" button al-
lows the user to select the size of the insert picture.
Five size selections are available, with the largest in-
sert equal to ¼ of the normal picture size.
In the PIP mode, the EXCH button swaps the main
and sub pictures. However this button has no effect
when Antenna B is the main picture source, and
Antenna A the sub picture source. Due to hardware
limitions:
• The Sub Tuner (Antenna A) is dedicated as
the PIP source.
• The Main Tuner (Antenna B) cannot be
selected as the PIP source.
Front Panel Buttons
Figure 1-4 shows the Front Panel buttons. Due to
dual functions of five of the buttons, 14 functions
can be performed. The primary function of the but-
tons is shown above each button. The secondary
functions are indicated below the buttons. The sec-
ondary functions are activated when in a menu mode.
• Volume Up and Down becomes Adjust Up
and Down
• Channel Up and Down becomes Adjust
Right and Left.
• AV Reset becomes Cancel
Diagnostic Mode
The Diagnostic Mode assists the servicer in isolating
the source of a problem, particularly those problems
causing the set to switch OFF (shutdown) during nor-
mal operation. When the Diagnostic Mode is acti-
vated, the front panel On/Off LED flashes a digital
code indicating the source of the problem.
The Diagnostic Mode can be automatic or servicer
activated.
Automatic Diagnostics
This occurs automatically when the TV is first con-
nected to an AC power source. Immediately after
power is applied:
• The LED flashes three times... indicating the
µPC has been initialized and is functioning.
• The LED does not flash... indicating the µPC
is not functioning.
Servicer Activated Diagnostics
Pressing the front panel "Input" and "Menu" but-
tons at the same time, and holding them for 5 sec-
onds, activates the Diagnostic Mode. The front panel
buttons must be used, not those on the Remote Con-
trol.
Figure 1-4: Front Panel Buttons
CODE
INDICATES
12
No error has occured
21
X-Ray Protect Shutdown
22
Short Protect Shutdown
23
Horizontal Deflection failure
24
Vertical Deflection failure
Table 1-4: Error Codes