Page 8-4
HV Regulation Key Points
• The sample of the HV from the CR Block is amplified and applied to the inverting input of the OP
Amp at pin 9 of IC501.
• The HV Adjustment voltage from the Convergence circuity is amplified and applied to the non
inverting input of the OP Amplifier, at pin 10 of IC501.
• The output of the OP Amplifier controls the conduction of Q501, determining the primary current of
T501.
• The primary current controls the amplitude of the drive signal applied to the FBT.