1. The following should always be observed for safety

 Caution:

Could lead to serious injury when operated incorrectly.

•  After reading this manual, be sure to keep it together with the instruction 

manual in a handy place on the customer’s site.

 : Indicates a part which must be grounded.

 Warning:

Carefully read the labels affixed to the main unit.

 Warning:

  Do not install the unit by yourself (user).

Improper or incomplete installation could cause fire, electric shock, injury due to 

the unit falling, or water leakage. Consult a qualified installer or the dealer from 

whom you purchased the unit.

  Follow the instructions detailed in the installation manual.

Incomplete installation could cause fire or electric shock, injury due to the unit 

falling, or leakage of water.

  Install the unit securely in a place that can bear the weight of the unit.

If the installation location cannot bear the weight of the unit, the unit could fall 

causing injury.

  Perform electrical work according to the installation manual and be sure to 

use an exclusive circuit. Do not connect other electrical appliances to the 

circuit.

If the capacity of the power circuit is insufficient or there is incomplete electrical 

work, it could result in a fire or an electric shock.

  Ground the unit correctly.

Do not connect the ground wire to a gas pipe, water pipe, lightning rod or tel

-

ephone ground. Defective grounding could cause electric shock.

  Do not damage the wires.

Damaged wires could cause fire.

  Be sure to shut off the main power when setting up the indoor P.C. board or 

wiring.

Failure to do so could cause electric shock.

  Use the specified wires to securely connect the indoor and outdoor units. 

Attach the wires firmly to avoid applying stress to the terminal block.

Improper connection could cause fire.

  Do not install the unit in a place where flammable gas may leak.

If gas leaks and accumulates around the unit, it could cause an explosion.

  Do  not  use  intermediate  connection  of  the  power  cord  or  the  extension 

cord. Do not connect many devices to one AC outlet.

It could cause a fire or an electric shock.

  Use the parts provided or specified parts for the installation work.

The use of defective parts could cause an injury or leakage of water due to a fire, 

an electric shock, the unit falling, etc.

  Securely attach the electrical cover to the indoor unit and the service panel 

to the outdoor unit.

If the electrical cover of the indoor unit and/or the service panel of the outdoor 

unit are not attached securely, dust, water, etc. could collect in the unit and could 

cause a fire or an electric shock.

  When installing or relocating the unit, make sure that no substance other 

than the specified refrigerant (R410A) enters the refrigerant circuit.

Any foreign substances in the refrigerant circuit can cause abnormal pressure 

rise or an explosion.

  Do not discharge the refrigerant into the atmosphere. Check that the refrig

-

erant gas does not leak after installation has been completed. If refrigerant 

leaks during installation, ventilate the room.

If refrigerant comes in contact with a fire, harmful gas could be generated.

If refrigerant gas leaks indoors, and comes into contact with the flame of a fan 

heater, space heater, stove, etc., harmful gases will be generated.

  Use appropriate tools and piping materials for installation.

The pressure of R410A is 1.6 times higher than R22. Not using the appropriate 

tools and materials, or improper installation could cause the pipes to burst caus

-

ing an injury.

  When pumping down the refrigerant, stop the compressor before discon

-

necting the refrigerant pipes.

If the refrigerant pipes are disconnected while the compressor is running and the 

stop valve is open, air could be drawn in and the pressure in the refrigeration cycle 

could become abnormally high, causing the pipes to burst.

  When installing the unit, securely connect the refrigerant pipes before start

-

ing the compressor.

If the compressor is started before the refrigerant pipes are connected and the 

stop valve is open, air could be drawn in and the pressure in the refrigeration cycle 

could become abnormally high, causing the pipes to burst.

  Fasten a flare nut with a torque wrench as specified in this manual.

If fastened too tight, a flare nut could break and cause refrigerant leakage.

  Install the unit according to national wiring regulations.

 Caution:

  Please follow applicable federal, state, or local codes to prevent potential 

leakage/electric shock. Or install a ground fault interrupt for the prevention 

of leakage and electric shock.

  Perform  the  drainage/piping  work  securely  according  to  the  installation 

manual.

If there is defect in the drainage/piping work, water could drip from the unit, and 

damage household items.

•  Please provide an exclusive circuit for the air conditioner and do not connect 

other electrical appliances to it.

•  Be sure to read “The following should always be observed for safety” before 

installing the air conditioner.

•  Be sure to observe the cautions specified here as they include important 

items related to safety.

•  The indications and meanings are as follows.

 Warning:

Could lead to death or serious injury.

  Do not touch the air inlet or the aluminum fins of the outdoor unit.

This could cause injury.

  Do not install the outdoor unit where small animals may live.

If small animals enter the unit and damage its electrical parts, it could cause a 

malfunction, smoke emission, or fire. Keep the area around the unit clean.

BH79A499H01_EN.indd   2

2018/09/04   16:49:03

Summary of Contents for TRANE NTXSKS09A112A

Page 1: ...le manuel d installation de l appareil intérieur pour une utilisation sûre et correcte MANUAL DE INSTALACIÓN Para un uso correcto y seguro lea detalladamente este manual y el manual de instalación de la unidad interior antes de instalar la unidad de aire acondicionado Air Conditioners NTXSKS09A112A NTXSKS12A112A NTXSKS15A112A POUR L INSTALLATEUR PARA EL INSTALADOR FOR INSTALLER Français Español En...

Page 2: ...ould cause a fire or an electric shock When installing or relocating the unit make sure that no substance other than the specified refrigerant R410A enters the refrigerant circuit Any foreign substances in the refrigerant circuit can cause abnormal pressure rise or an explosion Do not discharge the refrigerant into the atmosphere Check that the refrig erant gas does not leak after installation has...

Page 3: ...here there is high frequency or wireless equipment The outdoor unit produces condensate during the heating operation Select the in stallation place to ensure to prevent the outdoor unit and or the grounds from being wet by drain water or damaged by frozen drain water 2 Selecting the installation location When the piping is to be attached to a wall containing metals tin plated or metal netting use ...

Page 4: ... of specified thickness table on the above Excessive insulation may cause incorrect installation of the indoor unit and too little insulation may cause condensate to form The unit has flared connections on both indoor and outdoor sides Remove the valve cover from the outdoor unit then connect the pipe Refrigerant pipes are used to connect the indoor and outdoor units Be careful not to crush or ove...

Page 5: ... D Fig 4 4 4 4 Purging procedures and leak test 1 Remove service port cap of stop valve on the side of the outdoor unit gas pipe 2 Connect gauge manifold valve and vacuum pump to service port of stop valve on the gas pipe side of the outdoor unit 3 Run the vacuum pump 15 minutes or more 4 Check the vacuum with the gauge manifold valve then close it and shut off the vacuum pump 5 Leave as it is for...

Page 6: ...ure Be careful not to contact connecting cable with piping Caution Use care not to make miswiring Firmly tighten the terminal screws to prevent them from loosening After tightening pull the wires lightly to confirm that they do not move Warning Be sure to attach the service panel of the indoor unit securely If it is not attached correctly it could result in a fire or an electric shock due to dust ...

Page 7: ...local and national code 2 Use copper supply wires 3 Use wires rated 600V or more for the power supply cables and the indoor outdoor unit connecting cables 4 Install an earth longer than other cables 6 1 Gas charge Fig 6 1 1 Connect gas cylinder to the service port of stop valve 3 way 2 Execute air purge of the pipe or hose coming from refrigerant gas cylinder 3 Replenish specified amount of refrig...

Page 8: ...rigérant spécifié R410A ne pénètre dans le cir cuit de réfrigération La présence d une substance étrangère dans le circuit de réfrigération peut pro voquer une augmentation anormale de la pression voire une explosion Ne libérez pas le réfrigérant dans l atmosphère Vérifiez l absence de fuites de gaz réfrigérant une fois l installation terminée En cas de fuite de réfrigé rant pendant l installation...

Page 9: ... sulfurique source thermale En présence d équipements haute fréquence ou sans fil L unité extérieure produit de la condensation lors du mode de chauffage Choisir l endroit où le climatiseur sera monté de façon à éviter à l unité extérieure et ou aux sols d être mouillés par les condensats ou endommagés par le gel des condensats 2 Choisir l emplacement de l installation NTXSKS09A112A NTXSKS12A112A ...

Page 10: ...urs un matériau d isolation de l épaisseur spécifiée tableau à droite Une isolation trop épaisse peut être à l origine d une installation incorrecte de l unité interne une isolation trop fine peut provoquer la formation de condensation L unité comporte des raccordements évasés sur les faces intérieure et extérieure Retirez le couvercle de vanne de l unité externe et raccordez le tuyau Les conduite...

Page 11: ...es de purge et test de contrôle des fuites 1 Retirez le bouchon de l ouverture de service du robinet d arrêt du côté du tuyau de gaz de l unité externe 2 Raccordez la vanne du collecteur à jauge et la pompe à vide à l ouverture de service du robinet d arrêt du côté du tuyau de gaz de l unité externe 3 Faites fonctionner la pompe à vide pendant 15 minutes minimum 4 Contrôlez la dépression ainsi obt...

Page 12: ...on Faites attention de brancher les fils correctement Serrer fermement les vis des bornes pour les empêcher de se desserrer Puis tirer légèrement sur les fils pour vous assurer qu ils ne bougent pas Avertissement Veiller à visser correctement le panneau de service à l appareil extérieur Si le panneau de service n est pas bien installé de l eau des poussières etc pourraient pénétrer à l intérieur d...

Page 13: ...ucher les bornes S1 S2 et S3 lorsque l alimentation est sous tension S il faut placer un sectionneur entre les appareils extérieur et intérieur en utiliser un de type tripolaire 6 Entretien 6 1 Charge de Gaz Fig 6 1 1 Raccorder le tuyau de gaz au port de service de la vanne d arrêt à 3 voies 2 Purger l air du tuyau raccordé au tuyau de gaz réfrigérant 3 Ajouter la quantité spécifiée de réfrigérant...

Page 14: ...l circuito de refrigeración puede provocar una elevación anómala de la presión o una explosión No descargue el refrigerante en el ambiente Una vez acabada la instala ción compruebe que no haya fugas de gas refrigerante Si se producen fugas de refrigerante durante la instalación ventile la habitación Si el refrigerante entra en contacto con una llama podría generarse gas nocivo Si se produjeran pér...

Page 15: ...haya gas sulfúrico como en zonas de baños termales Donde haya algún equipo inalámbrico o de alta frecuencia La unidad exterior provoca condensación durante la función de calefacción Selec cione un lugar para la instalación en el que la unidad exterior y las tomas de tierra no se humedezcan con agua de drenaje ni se dañen debido a la congelación de este agua de drenaje 2 Selección del lugar de inst...

Page 16: ... tabla de la derecha El uso excesivo de aislante puede causar una instalación incorrecta de la unidad interior y el uso de una cantidad insuficiente de aislante puede provocar la condensación Las unidad tiene conexiones abocinadas en los lados interior y exterior Retire la tapa de la válvula de la unidad exterior y a continuación conecte la tubería Las tuberías de refrigerante se emplean para cone...

Page 17: ...ón situada en el lado de la tubería de gas de la unidad exterior 2 Conecte la válvula colectora de manómetro y la bomba de vacío al puerto de servicio de la válvula de retención en el lado de la tubería del gas de la unidad exterior 3 Ponga en funcionamiento la bomba de vacío durante 15 minutos o más 4 Compruebe el vacío con la válvula colectora de manómetro cierre luego esta válvula y detenga la ...

Page 18: ...gún las medidas que aparecen en la figura Tenga cuidado de que el cable de conexión no haga contacto con los tubos Cuidado Asegúrese de no realizar un mal cableado Apriete firmemente los tornillos de la terminal para evitar que se aflojen Tras apretarlos tire ligeramente de los cables para confirmar que no se muevan Atención Asegúrese de fijar firmemente el panel de servicio de la unidad exterior ...

Page 19: ...para los cables de la fuente de alimentación y los cables de conexión de las unidades inte rior exterior 4 Instale un cable de toma de tierra más largo que el resto de los cables 6 1 Carga de gas Fig 6 1 1 Conecte el cilindro de gas a la abertura de servicio de la válvula de parada de 3 vías 2 Purgue el aire del tubo o conducto procedente del cilindro de gas refrigerante 3 Vuelva a llenar la canti...

Page 20: ...his manual before handing it to the customer HEAD OFFICE 1340 SATELLITE BOULEVARD SUWANEE GA 30024 USA MITSUBISHI ELECTRIC TRANE HVAC US LLC Printed in Mexico BH79A499H01_cover4 indd 20 2018 08 31 14 37 18 Publication No DL SVN007A XX Published Nov 2018 BH79A499H01 ...

Reviews: