3 PROGRAMMING
3.2 Communication Example of Safety Communication Function
95
3
Setting in the local station
Connect the engineering tool to the Safety CPU of the local station and set parameters.
1.
Set the Safety CPU and add the module label. Also, add the safety program and safety global label. The setting method
is the same as that of the master station. (
Page 88 Setting in the master station and remote device station)
2.
Set the safety function module. Follow the same procedure as that for the master station. (
master station and remote device station)
3.
In the I/O assignment setting, set the master/local module for slot No.1.
4.
Add the module labels of the safety function module and master/local module. The addition method of the module label
is the same as that of the master station. (
Page 88 Setting in the master station and remote device station)
5.
Set the items in "Required Settings" as follows.
Navigation window
"Parameter"
"Module Information"
"RJ71GF11-T2"
"Required Settings"
6.
Set the refresh parameters. Set the same refresh parameters as those set for the master station. (
the master station and remote device station)
7.
Set "To Use or Not To Use the Safety Communication Setting" to "Use".
Navigation window
"Parameter"
"Module Information"
"RJ71GF11-T2"
"Application Settings"
"Safety
Communication Setting"
"To Use or Not To Use the Safety Communication Setting"
Master station (station No.0)
Local station (station No.1)
Setting
Remote device station (station No.2)