38
1 FUNCTIONS
1.4 Transient Transmission
When the networks consist of MELSEC iQ-R series and other series
Setting communication paths allows communication with the following networks configured with modules other than MELSEC
iQ-R series.
• Ethernet
• CC-Link IE Controller Network
• CC-Link IE Field Network
• MELSECNET/H
• MELSECNET/10
■
Setting method
Set communication paths in "Routing Setting" of "CPU Parameter". (
MELSEC iQ-R CPU Module User's Manual
(Application))
Communication test
Communication test checks if transient transmission data can be properly routed from the own station to the communication
target.
Take the following system configuration as an example of communication test procedure.
1.
Open the "Communication Test" window and enter
values for "Target Station" and "Communication Data
Setting".
[Diagnostics]
[CC-Link IE Field Diagnostics]
[Communication Test] button
2.
Click the [Execute Test] button to execute the
communication test. If an error occurs, take corrective
actions according to the error message.
Communication
target
Own station
(request source)
(Simple Motion module)
CC-Link IE
Field Network
CC-Link IE
Field Network
CC-Link IE
Field Network
Station
No.2
Station
No.1
Station
No.3
Station
No.0
Station
No.0
Station
No.2
Station
No.4
Station
No.0
(Relay
station 1)
Station
No.2
Station
No.3
(Relay
station 2)
Station
No.1
Network No.1
Network No.3
Network No.2