4 TROUBLESHOOTING
4.6 Event List
131
4
4.6
Event List
This section lists the events which occur in CC-Link IE Field Network.
System and operation are included in the event types.
System
Event code Overview
Cause
00100
Link-up
Link-up has occurred when the network cable connected to the external device was
connected.
00130
Receive frame error
Receive frame error was detected. Or, the network whose network type is different was
connected.
00500
<<Own station>> Baton pass return (network entry)
Baton pass of the own station was returned from interruption status to normal status.
00501
<<Another station>> Baton pass return (network
entry)
Baton pass of another station was returned from interruption status to normal status.
00502
All stations baton pass normalization (network entry
in all stations)
Baton pass was returned to normal status at all stations.
00510
<<Own station>> Data link restart (cyclic
transmission started)
Data link of the own station was restarted.
00511
<<Another station>> Data link restart (cyclic
transmission started)
Data link of another station was restarted.
00512
All stations data link normalization (cyclic
transmission in all stations started)
Data link was returned to normal status at all stations.
00513
<<Own station>> Data link start instruction
acceptance
Data link startup of the own station instruction was received.
00514
<<Own station>> Data link stop instruction
acceptance
Data link stop instruction of the own station was received.
00520
<<Own station>> Temporary error invalid station
setting instruction acceptance
Temporary error invalid station setting instruction was received.
00521
<<Own station>> Temporary error invalid station
cancel instruction acceptance
Temporary error invalid station cancel instruction was received.
00524
<<Another station>> Temporary error invalid station
setting execution
Temporary error invalid station was set at another station.
00525
<<Another station>> Temporary error invalid station
cancel execution
Temporary error invalid station was canceled at another station.
00530
<<Own station>> Reserved station cancel setting
instruction acceptance
Reserved station cancel setting instruction was received.
00531
<<Own station>> Reserved station enable setting
instruction acceptance
Reserved station enable setting instruction was received.
00534
<<Another station>> Reserved station cancel
setting execution
Reserved station cancel setting was executed at another station.
00535
<<Another station>> Reserved station enable
setting instruction execution
Reserved station enable setting was executed at another station.
00541
Receive parameter error resolution
A parameter error received from master station/control station was resolved. (Normal
parameter was received.)
00542
<<Own station>> Receive frame error line status
caution level
A receive frame error (line status: caution level) has been occurred.
00543
<<Another station>> Receive frame error line status
caution level
A receive frame error (line status: caution level) has been occurred.
00800
Link-down
Link-down occurred when network cable connected to the external device was
disconnected.
00C00
<<Own station>> Baton pass interruption
(departure from network)
Baton pass of the own station was interrupted.
00C01
<<Another station>> Baton pass interruption
(departure from network)
Baton pass of another station was interrupted.
00C02
Response error from/to another station
• Abnormal response was returned from another station when accessing another
station.
• Abnormal response was returned to another station when accessed from another
station.
00C10
<<Own station>> Data link stop (cyclic transmission
stopped)
Data link of the own station was stopped.
Summary of Contents for RD77GF16
Page 1: ...MELSEC iQ R Simple Motion Module User s Manual Network RD77GF4 RD77GF8 RD77GF16 RD77GF32 ...
Page 2: ......
Page 181: ...I 179 MEMO ...
Page 185: ......