2 EQUIPMENT SPECIFICATIONS
2.2 Motion CPU Module
37
2
Operation mode
■
Normal mode
The Motion CPU module operates based on the parameters, user programs stored in the standard ROM or the SD memory
card.
■
Ethernet information display mode
Displays Ethernet related information. Displays in the order of IP address, subnet mask, default router address, MAC address,
and link status.
During Ethernet information display mode, communication with MT Developer2, execution of Motion SFC programs, and axis
control cannot be performed.
The following is an example of a display in Ethernet information display mode.
Ex.
IP address: 192.168.3.39
Subnet mask pattern: 255.255.255.0
Default router IP address: 192.168.3.1
MAC address: 38-E0-8E-01-23-45
When the Ethernet parameters are not written in the Motion CPU, the addresses are displayed as follows.
• IP address: 192.168.3.39
• IP address: 0.0.0.0
• Default router IP address: 0.0.0.0
■
Installation mode
Mode for installing the operating system software. Only communication with MT Developer2 is possible. Execution of Motion
SFC programs, and axis control cannot be performed.
Disconnected
Connected
(10Mbps)
Connected
(100Mbps)
Full duplex
Half duplex
IP address
(192.168.3.39)
Subnet mask
(255.255.255.0)
Default router address
(192.168.3.1)
MAC address
(38-E0-8E-01-23-45)
Link status