2. About the product
・
The outdoor unit described in this manual is air-conditioning equipment that is designed only for human comfort.
・
The numeric values in the unit model name (e.g., PURY-P***YLM-A, PURY-EP***YLM-A) indicate the capacity
index of the unit.
・
This unit uses R410A refrigerant.
・
In this manual, the following terms are used, depending on the systems as shown in the table below.
R2 system
Hybrid City Multi system
Controllers that are connected to indoor units
BC controller
HBC controller
Heating medium on the indoor unit side
Refrigerant
Water or antifreeze liquid
・
CMB-WP108V-G can be connected to PURY-WP200YJM-A and PURY-WP250YJM-A, but not to PURY-(E)P-YLM-A
models of units.
・
PURY-P200YLM-A, PURY-P250YLM-A, PURY-EP200YLM-A and PURY-EP250YLM-A can be used in a
Hybrid City Multi system. Contact your dealer when connecting the larger capacity units in a Hybrid City Multi
system.
3. Combination of outdoor units
(1) P models
Outdoor unit model
Combination of outdoor units
PURY-P200YLM-A(-BS)
-
-
PURY-P250YLM-A(-BS)
-
-
PURY-P300YLM-A(-BS)
-
-
PURY-P350YLM-A(-BS)
-
-
PURY-P400YLM-A(-BS)
-
-
PURY-P400YSLM-A(-BS)
PURY-P200YLM-A(-BS)
PURY-P200YLM-A(-BS)
PURY-P450YLM-A(-BS)
-
-
PURY-P450YSLM-A(-BS)
PURY-P200YLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P500YLM-A(-BS)
-
-
PURY-P500YSLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P550YSLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P300YLM-A(-BS)
PURY-P600YSLM-A(-BS)
PURY-P300YLM-A(-BS)
PURY-P300YLM-A(-BS)
PURY-P650YSLM-A(-BS)
PURY-P300YLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P700YSLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P750YSLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P400YLM-A(-BS)
PURY-P800YSLM-A(-BS)
PURY-P400YLM-A(-BS)
PURY-P400YLM-A(-BS)
PURY-P850YSLM-A(-BS)
PURY-P400YLM-A(-BS)
PURY-P450YLM-A(-BS)
PURY-P900YSLM-A(-BS)
PURY-P450YLM-A(-BS)
PURY-P450YLM-A(-BS)
* "Twinning Kit" is required to connect combination units on site.
(2) EP models
Outdoor unit model
Combination of outdoor units
PURY-EP200YLM-A(-BS)
-
-
PURY-EP250YLM-A(-BS)
-
-
PURY-EP300YLM-A(-BS)
-
-
PURY-EP350YLM-A(-BS)
-
-
PURY-EP400YLM-A(-BS)
-
-
PURY-EP450YLM-A(-BS)
-
-
PURY-EP500YLM-A(-BS)
-
-
PURY-EP500YSLM-A(-BS)
PURY-EP250YLM-A(-BS)
PURY-EP250YLM-A(-BS)
PURY-EP550YSLM-A(-BS)
PURY-EP250YLM-A(-BS)
PURY-EP300YLM-A(-BS)
PURY-EP600YSLM-A(-BS)
PURY-EP300YLM-A(-BS)
PURY-EP300YLM-A(-BS)
PURY-EP650YSLM-A(-BS)
PURY-EP300YLM-A(-BS)
PURY-EP350YLM-A(-BS)
PURY-EP700YSLM-A(-BS)
PURY-EP350YLM-A(-BS)
PURY-EP350YLM-A(-BS)
PURY-EP750YSLM-A(-BS)
PURY-EP350YLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP800YSLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP850YSLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP450YLM-A(-BS)
PURY-EP900YSLM-A(-BS)
PURY-EP450YLM-A(-BS)
PURY-EP450YLM-A(-BS)
* "Twinning Kit" is required to connect combination units on site.