REV 2.5
77
4. To unlock the lamp cover in the right side
of the optical unit, turn the knob
clockwise.
5. Open the lamp cover.
6. Pull out the spare lamp from the lamp waiting position.
•
Pull out the lamp with right angle. Rough treatment may cause damage.
•
To replace the lamp in the lighting position, move it to the waiting position in advance by
manual lamp swap (chapter 2.1.3.3, on page 81).
•
Do not touch the glass envelope of the lamp. It may burn you.
Lamp cover
Lamp cover
Lamp waiting
position
Replacing lamp
Lamp lighting
position
Lamp waiting position
Knob
Summary of Contents for PH50 series