9
SPECIFICATIONS
4
4-1. Heat pump type (1)
Service Ref.
Item
Btu/h
W
kW
kW
A
A
kW
K
/min(CFM)
Pa(mmAq)
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle, voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Low-Med2-Med1-High)
External static pressure
Operation control & Thermostat
Noise level(Low-Med2-Med1-High)
Unit drain pipe O.D.
Dimensions
Weight
W
D
H
INDOOR UNIT
PCA-RP2.5GA
PCA-RP2.5GA
Cooling
20,500
6,000(2,700~6,700)
1.63
0.12
0.53
1.27
Heating
23,900
7,000(2,800~8,200)
2.03
0.12
0.53
1.27
Single phase, 50Hz, 220-230-240V
Munsell 0.70Y 8.59/0.97
Plate fin coil
Sirocco fan (direct) x 3
0.070
14-15-16-18(495-530-565-635)
0(direct blow)
Remote controller & built-in
37-39-41-43
26(1)
1,310(51-9/16)
680(26-3/4)
210(8-1/4)
34(75)
PUHZ-RP2.5VHA
Service Ref.
OUTDOOR
UNIT
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27˚C(80˚F), W.B. 19˚C (66˚F)
Outdoor
: D.B. 35˚C(95˚F), W.B. 24˚C (75˚F)
Heating : Indoor : D.B. 20˚C(68˚F)
Outdoor
: D.B. 7˚C(45˚F), W.B. 6˚C (43˚F)
Refrigerant piping length (one way) : 5m (16ft)
4. Above data based on indicated voltage
Indoor Unit Single phase 230V 50Hz
Outdoor Unit Single phase 230V 50Hz
2. Guaranteed operating range
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
D.B. 35˚C, W.B. 22.5˚C
D.B. 19˚C, W.B. 15˚C
D.B. 28˚C
D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C
D.B. 21˚C, W.B. 15˚C
D.B. -11˚C, W.B. -12˚C
Cooling
Heating
5. Refer to the service manual of outdoor unit for the outdoor unit's specifications.
3. Guaranteed voltage
198~264V, 50Hz
Cooling
16,000
4,700(2,300~5,400)
1.67
0.09
0.41
1.20
Heating
18,800
5,500(2,500~6,600)
1.71
0.09
0.41
1.20
Single phase, 50Hz, 220-230-240V
Munsell 0.70Y 8.59/0.97
Plate fin coil
Sirocco fan (direct) x 2
0.054
10-11-12-13(355-390-425-460)
0(direct blow)
Remote controller & built-in
37-38-40-42
26(1)
1,000(39-3/8)
680(26-3/4)
210(8-1/4)
27(60)
PUHZ-RP2VHA
PCA-RP2GA
PCA-RP2GA
Service Ref.
Item
Btu/h
W
kW
kW
A
A
kW
K
/min(CFM)
Pa(mmAq)
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle, voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Low-Med2-Med1-High)
External static pressure
Operation control & Thermostat
Noise level(Low-Med2-Med1-High)
Unit drain pipe O.D.
Dimensions
Weight
W
D
H
Service Ref.
INDOOR UNIT
OUTDOOR
UNIT
OC311--1.qxp 04.5.31 1:03 PM Page 9