12
4-2. Heat pump type (2)
Service Ref.
Item
Btu/h
W
kW
kW
A
A
kW
K
/min(CFM)
Pa(mmAq)
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle, voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Low-Med2-Med1-High)
External static pressure
Operation control & Thermostat
Noise level(Low-Med2-Med1-High)
Unit drain pipe O.D.
Dimensions
Weight
W
D
H
INDOOR UNIT
PCA-RP2.5GA
PCA-RP2.5GA
Cooling
22,500
6,600
2.62
0.12
0.53
1.27
Heating
24,700
7,250
2.66
0.12
0.53
1.27
Single phase, 50Hz, 220-230-240V
Munsell 0.70Y 8.59/0.97
Plate fin coil
Sirocco fan (direct) x 3
0.070
14-15-16-18(495-530-565-635)
0(direct blow)
Remote controller & built-in
37-39-41-43
26(1)
1,310(51-9/16)
680(26-3/4)
210(8-1/4)
34(75)
Service Ref.
OUTDOOR
UNIT
PUH-P2.5VGAA
PUH-P2.5VGAA.UK / PUH-P2.5YGAA.UK
PUH-P2.5VGAA
1
.UK / PUH-P2.5YGAA
1
.UK
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27˚C(80˚F), W.B. 19˚C (66˚F)
Outdoor
: D.B. 35˚C(95˚F), W.B. 24˚C (75˚F)
Heating : Indoor : D.B. 20˚C(68˚F)
Outdoor
: D.B. 7˚C(45˚F), W.B. 6˚C (43˚F)
Refrigerant piping length (one way) : 5m (16ft)
4. Above data based on indicated voltage
Indoor Unit Single phase 230V 50Hz
Outdoor Unit Single phase 230V 50Hz / 3 phase 400V 50Hz
2. Guaranteed operating range
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
D.B. 35˚C, W.B. 22.5˚C
D.B. 19˚C, W.B. 15˚C
D.B. 28˚C
D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C
D.B. 24˚C, W.B. 18˚C
D.B. -11˚C, W.B. -12˚C
Cooling
Heating
5. Refer to the service manual of outdoor unit for the outdoor unit's specifications.
3. Guaranteed voltage
198~264V, 50Hz
Cooling
18,300
5,350
2.35
0.09
0.41
1.20
Heating
21,200
6,200
2.36
0.09
0.41
1.20
Single phase, 50Hz, 220-230-240V
Munsell 0.70Y 8.59/0.97
Plate fin coil
Sirocco fan (direct) x 2
0.054
10-11-12-13(355-390-425-460)
0(direct blow)
Remote controller & built-in
37-38-40-42
26(1)
1,000(39-3/8)
680(26-3/4)
210(8-1/4)
27(60)
PCA-RP2GA
PCA-RP2GA
Service Ref.
Item
Btu/h
W
kW
kW
A
A
kW
K
/min(CFM)
Pa(mmAq)
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
Function
Capacity
Total input
Service Ref.
Power supply(phase, cycle, voltage)
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Low-Med2-Med1-High)
External static pressure
Operation control & Thermostat
Noise level(Low-Med2-Med1-High)
Unit drain pipe O.D.
Dimensions
Weight
W
D
H
Service Ref.
INDOOR UNIT
OUTDOOR
UNIT
PUH-P2VGAA
PUH-P2VGAA.UK / PUH-P2YGAA.UK
PUH-P2VGAA
1
.UK / PUH-P2YGAA
1
.UK
OC311--1.qxp 04.5.31 1:03 PM Page 12