64
CNF1
To fan motor
V
FG
(Rotate signal)
(Voltage between
right pins of PC931,
pin 3 and pin 4)
(Correspond to
(CNF1 (+)- (−))
V
SP
(Rotate instruction)
(Voltage between pins
of C930): 0 V DC
(when stopped),
1.8 - 6.5 V DC
(when operated)
(Same as
(CNF1 (+)- (−))
Discharge temperature
thermistor (RT62)
Outdoor heat exchanger
temperature thermistor
(RT68)
CNTH1
CNTH2
Ambient temperature
thermistor
(RT65)
SW1
LED3
LED2
LED1
SW2
SW871
CNAC
to outdoor power P.C. board
220 - 230 - 240 V AC
Input
F711 FUSE
T3.15AL250V
CN741
Signal translation
(To Communication
adaptor board)
(-)
CN701
Signal transmission
(To power board)
5 V DC pulse wave
CN702
Signal transmission
(To power board)
5 V DC pulse wave
(+)
(+)
(-)
(-)
(-)
CN63H
High
pressure
switch
CNDC
Bus-bar
voltage
290 - 370
V DC
Bus-bar voltage
290 - 370 V DC
15 V DC
CN601
Room A
Input
Room B
Room C
LEV: 12 V DC
pulse wave
CN713 Valve coil
220 - 230 - 240 V AC
Output
CN611
Serial signal 12 ~ 24 V
CN791
LEV Room A
(
CN792
LEV Room B
CN793
LEV Room C
)
15 V
15 V
Rotate instruction
(Constant voltage)
Rotate signal
(Pulse wave)
CN714 Defrost heater
220 - 230 - 240 V AC
Output
Defrost thermistor (RT61)
CN797
LEV Room R
220 - 230 - 240 V AC
0
100
200
300
400
500
600
700
800
0 10 20 30 40 50 60 70 80 90 100 110 120
Temperature( )
Discharge temperature thermistor (RT62)
Resistance(k )
Thermistor R100 = 13.36 k
Ω
± 2%
B constant = 4014 ± 2%
Rt = 13.36exp{4014( )}
273+t
1
373
1
-20 -10
0
10
20
30 40 (ºC)
100
90
80
70
60
50
40
30
20
10
0
Resistance (kΩ)
Temperature
273+t
1
298
1
Thermistor R25 = 10 k
Ω
± 2%
B constant = 3950 ± 2%
Rt = 10exp{3950( )}
Defrost thermistor (RT61)
Ambient temperature thermistor (RT65)
Outdoor heat exchanger temperature
thermistor (RT68)
MXZ-3HA50VF
2. Outdoor control P.C. board
OBH828A