15
Indoor model
Function
Indoor unit power supply
Air flow (High/Med./Low)
Power outlet
Running current
Power input
Power factor
Starting current
Fan motor current
Model
Winding
resistance (at 20
:
)
Dimensions W
O
H
O
D
Weight
Air direction
Sound level (High/Med./Low)
Fan speed (High/Med./Low)
Fan speed regulator
Thermistor RT11 (at 25
:
)
Thermistor RT12 (at 25
:
)
Outdoor model
Capacity
Dehumidification
Outdoor air flow
Power outlet
Running current
Power input
Auxiliary heater
Power factor
Starting current
Compressor motor current
Fan motor current
Model
Output
Winding
resistance (at 20
:
)
Model
Winding
resistance (at 20
:
)
Dimensions W
O
H
O
D
Weight
Sound level
Fan speed
Fan speed regulator
Refrigerant filling
capacity (R410A)
Refrigerating oil (Model)
K
/h
A
A
W
%
A
A
"
mm
kg
dB
rpm
k
"
k
"
kW
R
/h
K
/h
A
A
W
A(kW)
%
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
MSC-A09WV -
E1
(Unit C ,D)
Cooling
Single phase 230V,50Hz
474/384 /306
10
0.17
35
90
—
0.17
RC4V19-LA
WHT-BLK 413
BLK-RED 334
815
O
278
O
217
9
5
36/31 /25
900/770 /650
3
10
10
MSC-A12WV -
E1
(Unit A ,B)
Cooling
Single phase 230V,50Hz
582/444 /324
10
0.19
40
92
—
0.19
RC4V19-KA
WHT-BLK 316
BLK-RED 299
815
O
278
O
217
10
5
40/33 /26
930/760 /600
3
10
10
Electrical
data
Fan
motor
Special
remarks
Compressor
Electrical
data
Fan
motor
Special
remarks
Capacity
Coefficient of performance (C.O.P)
Outdoor unit power supply
Indoor unit No.
Capacity
MUX-A26WV -
E1
Single phase 230V,50Hz
2,760
20
—
52
0.53
MC1 : RN145VHSHT, MC2 : RN125VHSHT
MC1 : 1,000, MC2 : 800
RA6V60-FA
WHT-BLK 79
BLK-RED 80
840
O
850
O
330
76
52
730
1
1.05 (Room A+B)
1.05 (Room C+D)
MC1 : 620 (NEO22), MC2 : 350 (NEO22)
w
w
w
w
Single
A or B
3.4
1.2
5.28
1,180
97.2
4.75
2.79
Single
C or D
2.75
1.1
4.54
1,015
97.2
4.01
2.62
Double
A+B
1.95
O
2
0.2
O
2
5.46
1,210
96.4
4.93
3.02
Double
A+C or A+D
or
B+C or B+D
Triple
A+B+C
or
A+B+D
Triple
A+C+D
or
B+C+D
3.4+2.7
1.2+1.1
9.57
2,095
95.2
9.04
2.81
Double
C+D
1.7
O
2
0.3
O
2
4.78
1,060
96.4
4.25
3.01
1.95
O
2+2.8
0.2
O
2+1.1
9.61
2,105
95.2
9.08
3.02
3.4+1.7
O
2
1.2+0.3
O
2
9.66
2,140
96.3
9.13
3.02
Four
A+B+C+D
1.95
O
2+1.7
O
2
0.2
O
2+0.3
O
2
9.75
2,210
98.6
9.22
3.09
C-R 2.43
C-S 3.80
MC1 :
, MC2 :
C-R 2.86
C-S 5.72
w
w
w
w
w
w
w
w
w
w
w
w
w
NOTE: Test conditions are based on ISO 5151.
Cooling : Indoor
DB27°C WB19°C
Heating : Indoor
DB20°C
Outdoor DB35°C WB24°C
Outdoor
DB 7°C/WB 6°C
Indoor-Outdoor piping length 5m
w
Reference value
OB307A1.qxp 03.2.19 3:57 PM Page 15