67
MSC-A07WV -
: MUH-A07WV -
E1
E1
PERFORMANCE DATA
HEAT operation (230V)
MSC-A09WV -
: MUH-A09WV -
E1
E1
OUTDOOR WB(
;
)
INDOOR
-10
-5
0
5
10
15
20
DB(
;
)
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
1.58
449
1.90
538
2.23
607
2.55
656
2.88
697
3.18
718
3.50
731
21
1.50
483
1.80
573
2.13
635
2.43
683
2.75
718
3.05
738
3.36
766
26
1.35
518
1.68
607
1.98
669
2.30
718
2.63
752
2.93
773
3.25
794
CAPACITY : 2.5 kW INPUT : 690 W
OUTDOOR WB(
;
)
INDOOR
-10
-5
0
5
10
15
20
DB(
;
)
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
1.92
546
2.32
655
2.71
739
3.11
798
3.51
848
3.87
874
4.27
890
21
1.83
588
2.20
697
2.59
773
2.96
832
3.36
874
3.72
899
4.10
932
26
1.65
630
2.04
739
2.41
815
2.81
874
3.20
916
3.57
941
3.97
966
CAPACITY : 3.05 kW INPUT : 840 W
MSC-A12WV -
: MUH-A12WV -
E1
E1
OUTDOOR WB(
;
)
INDOOR
-10
-5
0
5
10
15
20
DB(
;
)
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
Q
INPUT
15
2.46
702
2.96
842
3.47
950
3.98
1026
4.49
1091
4.95
1123
5.46
1145
21
2.34
756
2.81
896
3.32
994
3.78
1069
4.29
1123
4.76
1156
5.25
1199
26
2.11
810
2.61
950
3.08
1048
3.59
1123
4.10
1177
4.56
1210
5.07
1242
CAPACITY : 3.9 kW INPUT : 1080 W
NOTE
Q:Total capacity (kW) INPUT:Total power input (W) DB:Dry-bulb temperature WB:Wet-bulb temperature
OB307A3.qxp 03.2.19 4:05 PM Page 67