![Mitsubishi Electric Mr.SLIM PCA-RP100KAQ Installation Manual Download Page 10](http://html.mh-extra.com/html/mitsubishi-electric/mr-slim-pca-rp100kaq/mr-slim-pca-rp100kaq_installation-manual_1810148010.webp)
)XQFWLRQVHWWLQJV
)XQFWLRQVHWWLQJRQWKHXQLW6HOHFWLQJWKHXQLWIXQFWLRQV
)RUZLUHGUHPRWHFRQWUROOHU)LJ
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.
Go to the function setting mode.
Switch OFF the remote controller.
Press the FILTER
and TEST RUN
buttons simultaneously and hold
them for at least 2 seconds. FUNCTION will start to blink.
Use the
buttons to set the refrigerant address (
) to 00.
Press
button and [--] will start to blink in the unit number (
) display.
Use the
buttons to set the unit number (
) to 00.
Press the MODE button
to designate the refrigerant address/unit number. [--]
will blink in the mode number (
) display momentarily.
Press the
buttons to set the mode number (
) to 04.
Press the
button and the current set setting number (
) will blink.
Use the
button to switch the setting number in response to the power supply
voltage to be used.
Power supply voltage
240 V
: setting number = 1
220 V, 230 V : setting number = 2
Press the MODE button
and mode and the setting number (
) and (
) will
FKDQJHWREHLQJRQFRQVWDQWO\DQGWKHFRQWHQWVRIWKHVHWWLQJFDQEHFRQ¿UPHG
Press the FILTER
and TEST RUN
buttons simultaneously for at least 2
seconds. The function selection screen will disappear momentarily and the air
conditioner OFF display will appear.
)RUZLUHOHVVUHPRWHFRQWUROOHU)LJ
Changing the power voltage setting
• Be sure to change the power voltage setting depending on the voltage used.
Going to the function select mode
Press the
CHECK
button
twice continuously.
(Start this operation from the status of remote controller display turned off.)
CHECK
is lighted and “00” blinks.
Press the
temp button
once to set “50”. Direct the wireless remote control-
ler toward the receiver of the indoor unit and press the
h
button
.
Setting the unit number
Press the
temp buttons
and
to set the unit number “00”. Direct the
wireless remote controller toward the receiver of the indoor unit and press the
min
button
.
Selecting a mode
Enter 04 to change the power voltage setting using the
temp buttons
and
. Direct the wireless remote controller toward the receiver of the indoor
unit and press the
h
button
.
Current setting number:
1 = 1 beep (1 second)
2 = 2 beeps (1 second each)
3 = 3 beeps (1 second each)
Selecting the setting number
Use the
temp buttons
and
to change the power voltage setting to
01 (240 V). Direct the wireless remote controller toward the sensor of the indoor
unit and press the
h
button
.
To select multiple functions continuously
Repeat steps
and
to change multiple function settings continuously.
Complete function selection
Direct the wireless remote controller toward the sensor of the indoor unit and
press the
button
.
Note: Whenever changes are made to the function settings after installation
or maintenance, be sure to record the changes with a mark in the “Setting”
column of the Function table.
)XQFWLRQVHWWLQJRQWKHUHPRWHFRQWUROOHU
Refer to the indoor unit operation manual.
(OHFWULFDOZRUN
Function table
Select unit number 00
Mode
Settings
Mode no.
Setting no. Initial setting
setting
Power failure automatic recovery
Not available
01
1
Available
+
2
ȅ
Indoor temperature detecting
Indoor unit operating average
02
1
ȅ
Set by indoor unit’s remote controller
2
Remote controller’s internal sensor
3
LOSSNAY connectivity
Not Supported
03
1
ȅ
Supported (indoor unit is not equipped with outdoor-air intake)
2
Supported (indoor unit is equipped with outdoor-air intake)
3
Power voltage
240 V
04
1
220 V, 230 V
2
ȅ
Fig. 6-8
CHECK
CHECK
ON/OFF
TEMP
FAN
VANE
TEST RUN
AUTO STOP
AUTO START
h
min
LOUVER
MODE
CHECK
RESET
SET
CLOCK
CHECK
Fig. 6-9
CHECK
CHECK
Mode number
Setting number
Refrigerant address
Unit number
PAR-21MAA
ON/OFF
FILTER
CHECK
OPERATION
CLEAR
TEST
TEMP.
MENU
BACK
DAY
MONITOR/SET
CLOCK
ON/OFF