13
2. PERFORMANCE CURVE
NOTE : A point on the curve shows the reference point.
MS09NW
MS09NW2
MS12NN
MS12NN2
MU09NW
MU09NW2
MU12NN
MU12NN2
MS15NN
MS15NN2
MS17NN
MS17NN2
MU15NN
MU15NN2
MU17NN
MU17NN2
71
67
63
71
67
63
71
67
63
71
67
63
Total power consumption (kW)
T
otal capacity (
o
10 Btu/h)
Outdoor intake air DB temperature (
-
F)
Outdoor intake air DB temperature (
-
F)
Indoor intake air WB temperature (
-
F)
Indoor intake air WB temperature (
-
F)
Indoor intake air WB temperature (
-
F)
Indoor intake air WB temperature (
-
F)
Cooling capacity
SHF at rating condition = 0.7
= 279CFM
= 0.26
Airflow
Bypass Factor
Cooling capacity
SHF at rating condition = 0.71
= 392CFM
= 0.17
Airflow
Bypass Factor
12
10
8
6
1.2
65
75
85
95
105
115
67
75
85
95
105
115
0.8
0.6
Total power consumption (kW)
T
otal capacity (
o
10 Btu/h)
16
14
12
10
8
2
1
71
67
63
71
67
63
71
67
63
71
67
63
Indoor intake air WB temperature (
-
F)
Indoor intake air WB temperature (
-
F)
Cooling capacity
SHF at rating condition = 0.7
= 367CFM
= 0.22
Airflow
Bypass Factor
67
75
85
95
105
115
Total power consumption (kW)
T
otal capacity (
o
10 BTU/h)
18
16
14
12
2
1
Outdoor intake air DB temperature (
-
F)
Indoor intake air WB temperature (
-
F)
Indoor intake air WB temperature (
-
F)
Cooling capacity
SHF at rating condition = 0.65
= 417CFM
= 0.24
Airflow
Bypass Factor
67
75
85
95
105
115
Total power consumption (kW)
T
otal capacity (
o
10 BTU/h)
20
18
16
14
2
1
Outdoor intake air DB temperature (
-
F)