11
w
Height difference
should be within
25ft regardless of
which unit, indoor
or outdoor
position is high.
w
Max. Height
difference 25ft
Additional Piping
Max. length
A
Indoor
unit
Outdoor unit
MAX. HEIGHT DIFFERENCE
Models
MS09NW MS09NW2
MS12NN MS12NN2
MS15NN MS15NN2
MS17NN MS17NN2
Additional piping
Max. length : ft
A
49
Gas
[
3/8
[
5/8
Piping size O.D. : in.
Length of connecting pipe : in.
Liquid
[
1/4
Indoor unit
16-15/16
Outdoor unit
0
MAX. REFRIGERANT PIPING LENGTH & MAX. HEIGHT DIFFERENCE
MSM30NN MSM30NN2
Indoor unit A
MS09NW
w
Max. Height
difference 25ft
Indoor unit B
MS09NW
Outdoor unit
MUM30NN
MUM30NN2
Indoor unit C
MS15NN
Max. Length
65ft
w
Max. Height
difference 25ft
w
Max. Height
difference 25ft
Max. Length
65ft
Max. Length
65ft
Model
Additional piping
Max. length : ft
A
Length of connecting pipe : in.
MS09NW
MS15NN
65
Gas
Liquid
Indoor unit
16-15/16
Piping size O.D. : in.
0
[
3/8
[
5/8
[
1/4
Outdoor unit
MAX. HEIGHT DIFFERENCE