5.2.2
Configuration for communication with GX IEC Developer
Generally, positioning control is performed via a CC-Link network in applications where an addi-
tional PLC system is used for automation tasks as well as the integrated controller in the ampli-
fier. In this example we will thus only provide detailed descriptions of the settings required to
integrate the servo amplifier in your project.
Procedure:
How to open an existing project in GX IEC Developer:
햲
Select
Network
���
in the project directory tree in the left window.
햳
Select
CC-Link
���
in the
Network Parameter
box.
햴
This opens the window
Network parameters: Setting the CC-Link list
where you can now
enter the settings shown in Fig. 5-6
���
.
Positioning via a CC-Link Network
CC-Link Communication Settings
MR-J3-T
5 - 35
Fig. 5-6:
Settings required in GX IEC Developer for CC-Link communication between
the controller and the servo amplifier
���
���
���
(a)
(b)
(c)