2. PROJECT CREATION
2.1 Project file operation
Setting the automatic recognition of the inverter and FR Configurator2
(Ethernet connection)
• To connect the inverter and FR Configurator2 via Ethernet, refer to the following table to check the settings of the relay
device and parameters.
Model
Through
Pr.
Name
Setting
FR-A800-E
FR-F800-E
Not connected
1427
Ethernet function selection 1
Set a combination of "5001" (or "5002") and
"45237" in any two of the parameters.
1428
Ethernet function selection 2
1429
Ethernet function selection 3
1442 to 1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the personal computer.
Programmable
controller
1427
Ethernet function selection 1
Set "5001" in any of the parameters.
1428
Ethernet function selection 2
1429
Ethernet function selection 3
1442
to
1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the Ethernet module.
GOT to
programmable
controller
1427
Ethernet function selection 1
Set "5001" in any of the parameters.
1428
Ethernet function selection 2
1429
Ethernet function selection 3
1442
to
1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the Ethernet module.
FR-A800-E-
R2R
Not connected
1076
Ethernet function selection 1
Set a combination of "5001" (or "5002") and
"45237" in any two of the parameters.
1077
Ethernet function selection 2
1078
Ethernet function selection 3
1442 to 1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the personal computer.
Programmable
controller
1076
Ethernet function selection 1
Set "5001" in any of the parameters.
1077
Ethernet function selection 2
1078
Ethernet function selection 3
1442
to
1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the Ethernet module.
GOT to
programmable
controller
1076
Ethernet function selection 1
Set "5001" in any of the parameters.
1077
Ethernet function selection 2
1078
Ethernet function selection 3
1442
to
1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the Ethernet module.
FR-E800-
(SC)E
Not used
1427
Ethernet function selection 1
Set a combination of "5001" (or "5002") and
"45237" in any two of the parameters.
1428
Ethernet function selection 2
1429
Ethernet function selection 3
1430
Ethernet function selection 4
1442 to 1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the personal computer.
Programmable
controller
1427
Ethernet function selection 1
Set "5001" in any of the parameters.
1428
Ethernet function selection 2
1429
Ethernet function selection 3
1430
Ethernet function selection 4
1442 to 1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the Ethernet module.
GOT to
programmable
controller
1427
Ethernet function selection 1
Set "5001" in any of the parameters.
1428
Ethernet function selection 2
1429
Ethernet function selection 3
1430
Ethernet function selection 4
1442
to
1448
IP filter address (Ethernet)
Set the IP address to within the IP address
range of the Ethernet module.