122
3. FUNCTION
3.3 Convert
3.3.3
Connection setting for the convert function
Select [Specify source] in the convert window to display the "Source" window.
To perform the convert function from the inverter connected via communication, select [Read from connected inverter] and click
[Connection setting] to display the [Connection setting] window. For the "Connection setting" window, refer to
.
3.3.4
Convert procedures
To convert from the directly connected inverter
NOTE
• Perform this procedure while the inverter is stopped. Do not give a start command to the inverter.
1.
Select [Specify source] in the "Convert" window to display the "Source" window.
Symbol
Name
Function/description
A
Specify source
Displays the "Source" window. Select the source parameter file (*.pr4, *.pr3, *.prm) or the source
inverter model.
B
Convert...
Displays the "Convert" sub window.
C
Reflect...
Displays the "Reflect" window. The converted setting of parameters will be reflected to the
parameter list of the specified inverter. The setting can also be saved to a parameter file (*.pr4).
(Select [Save in file] or [Reflect to project] after converting the parameters.)
D
Source inverter
information
The model of the source inverter and the options connected to it are displayed.
E
Source parameter list
The list of the parameter settings read from the source is displayed.
F
Target inverter
information
The model of the target inverter and the options connected to it are displayed.
G
Target parameter list
The list of the converted parameter settings is displayed.
H
Help
Displays the help window.
Select [Specify source]