
160
3. FUNCTION
3.8 AI fault diagnosis
AI fault diagnosis result screen (details of the AI fault diagnosis)
Symbol
Name
Function/description
A
St. No. (Station number)
Select a station registered in the project.
B
Operation mode button
Switch between the operation modes of the inverter.
C
Operation mode indication Displays the operation mode.
D
Batch read
Reads all the parameter setting values of the selected inverter.
Read
Reads the selected parameter setting values of the selected inverter.
Batch write
Writes all the selected parameter setting values in the setting value column to the selected inverter.
Write
Writes all selected parameter setting values to the selected inverter.
E
Cause
Shows probable causes of the fault.
F
Action
Corrective actions are suggested.
G
No.
Shows the parameter number.
Name
Shows the parameter name.
Setting range
Shows the setting range of the parameter setting value.
Min. unit
Shows the minimum setting unit of the parameter setting value.
Initial value
Shows the factory default parameter setting values of the inverter.
Setting value
Inputs the value to be written to the inverter. The yellow background color shows that the value has
been changed after the startup.
A
F
E
C
B
D
G