112
3. FUNCTION
3.1 Parameter list
Point table (FR-A800)
Set parameters related to point tables.
Point table (FR-E800)
Set parameters related to point tables.
Symbol
Name
Function/description
A
No.
Point table number
B
Target position
Set the position feed length. (Refer to
Pr.465
to
Pr.494
.)
C
Maximum speed
Set the maximum speed for the target parameter of each point table. If a checkbox is selected, the
maximum speed of the point table 1, 2, or 3 is applied ("9999" is set in the corresponding
parameter (
Pr.24
to
Pr.27
, and
Pr.232
to
Pr.239
)).
D
Acceleration time
Set the acceleration time for the target parameter of each point table.
E
Deceleration time
Set the deceleration time for the target parameter of each point table.
F
Dwell time
Set the waiting time before starting the position command of the next point table.
G
Sign
Select the polarity of position data.
H
Command method
Select the absolute or incremental position command.
I
Operation method
Select the individual, continuous, or repeat operation.
When continuous operation is selected, next point table is executed after a command has been
executed. For continuous operation, select "individual" in [Operation method] of the last point
table.
Individual operation executes the selected point table only.
When repeat operation is selected, the selected positioning operation is repeated.
Setting range
Minimum
increments
A
B
C
D
E
F
G
H
I
A
B
C
D
E
F
G
H
Setting range
Minimum
increments