48
8.1.2 RS-232C configuration
(1) Outline
A single axis of servo amplifier is operated.
(2) Cable connection diagram
Wire as shown below. The communication cable for connection with the personal computer (MR-
CPCATCBL3M) is available.
12
11
2
1
TXD
GND
RXD
GND
FG
Personal computer
connector D-SUB25 (socket)
(Note 4)
(Note 3) 15m(590.55inch) max.
(Note 1)
Servo amplifier
CN3 connector
Plate
D-SUB29 (socket) for PC-98
compatible controller
TXD
RXD
GND
RTS
CTS
DSR
DTR
3
2
5
7
8
6
4
TXD
GND
RXD
GND
CN3 connector 2
CN3 connector 1
CN3 connector 12
CN3 connector 11
SD
RD
SG
RS
CS
2
3
7
4
5
(Note 2)
Note: 1. 3M's CN3 connector
Connector: 1020-3000VE
Shell kit: 10320-52F0-008
2. For the PC-98 series. The PC-98 series also has the half-pitch type.
3. 15m (590.55inch) max. in environment of little noise.
4. For the PC-AT compatible.
CHARGE
MITSUBISHI
RS-232C
Controller such as
personal computer
MR-J2S-A-S061
To CN3
Servo amplifier