Name and Function
Initial Value
Unit
Setting Range
18 *DMD Status
display
selection
Used to select the status display shown at power-on .
0000 0000h
to
1F1Fh
B
asi
c p
ara
meters
19 *BLK Parameter
block
Used to select the reference and write ranges of the parameters.
Parameter No.
Set Value
Operation
#00
to
#18
#19
#20
to
#53
#54
to
#90
Reference
{
{
×
×
0000
(Initial value)
Write
{
{
×
×
Reference
×
{
×
×
000A
Write
×
{
×
×
Reference
{
{
{
×
000B
Write
{
{
×
×
Reference
{
{
{
×
000C
Write
{
{
{
×
Reference
{
{
{
{
000E
Write
{
{
{
{
0000 0000h
to
FFFFh
Status display shown at power-on
00: Current position
01: Command position
02: Command remaining distance
03: Point table No.
04: Cumulative feedback pulses
05: Motor speed
06: Droop pulses
07: Override voltage
08: Limiting torque voltage
09: Regenerative load ratio
0A: Effective load ratio
0B: Peak load ratio
0C: Instantaneous torque
0D: Within one-revolution position (low)
0E: Within one-revolution position (high)
0F: ABS counter
10: Load inertia moment ratio
11: Bus voltage
0
0