![Mitsubishi Electric MELSERVO-J2S-S061 Specifications And Instruction Manual Download Page 40](http://html.mh-extra.com/html/mitsubishi-electric/melservo-j2s-s061/melservo-j2s-s061_specifications-and-instruction-manual_239181040.webp)
39
BCN-B11127-479*
Class No. Symbol
Name and Function
Initial
Value
Unit Setting
Range
52
53
LNP Position range output address
Used to set the address decrement side position range output address. Set the
same sign to parameters No.52 and 53. Setting of different signs will result in a
parameter error.
Set address:
Upper 3
digits
Lower 3
digits
Parameter No. 53
Parameter No. 52
0
10
STM
m
999999
to
999999
54 *OP5 For
manufacturer
setting
0000
55 *OP6 Optional function 6
Servo on response in alarm reset operation.
Used to select the operation to be performed when the alarm reset signal
switches on.
0000 0000h
to
1111h
56 *OP7 Optional function 7
Used to select the current position display mode.
Item
Display of positioning
Display of role feeding
Current
position
Display actual position
from machine home
position
Display actual position from
power on
A
u
tom
a
tic
operati
on m
ode
Comman
ded
position
Display commanded
position from machine
home position
Display target position in
stop motion.
Count start from 0 at start
signal turned on.
And display commanded
position till target position
Current
position
Display commanded
position from machine
home position
Display target position in
stop motion.
Count start from 0 at start
signal turned on.
And display commanded
position till target position
M
anual
operati
on
Comman
ded
position
Display commanded
position from machine
home position
Display target position in
stop motion.
And display selected
position data at start signal
turned on.
0000 0000h
to
1111h
0
0 0
Operation to be performed when the
alarm reset signal switches on
0: Base circuit not switched off
1: Base circuit switched off
0
0
Electric gear cal. error clear selection
0: Invalid
1: Valid
Current position / Commanded position display selection
0: Display of positioning
1: Display of role feeding