13
1. Name and Function of Each Section
Function of Operation Buttons
The function of each operation button varies
depending on how to press the button.
<Meaning of marks>
○
: Press,
□
: Press for 1 second or more,
◎
: Press for 2 seconds or more,
――
: Press simultaneously
Operation
Mode
Button name
Function
SET
-
+
RESET MAX/MIN PHASE DISPLAY
Op
e
ra
ting
mod
e
D
is
p
lay
s
w
it
c
h
ing
○
Switch the measurement screen.
○
○
Switch the measurement screen in the reverse direction.
○
Switch phase display.
Switch between the harmonic RMS value and distortion ratio
on the harmonics display screen.
○
Enter/Exit the Max/Min value screen.
◎
Enter the cyclic display mode for measurement screen. Refer
to
◎
Enter the cyclic display mode for phase. Refer to
Switch between the harmonic RMS value and distortion ratio
in cyclic mode on the harmonics display screen.
◎
◎
Change the units such as Wh, varh, and VAh or display the
lower-digit enlarged view.
Refer to
Mea
s
u
re
d
v
a
lue
c
lea
rn
e
s
s
/
A
lar
m
re
s
e
t
◎
Clear the maximum and minimum
values displayed on the screen.
They are available
on the Max/Min
value screen.
◎
◎
Clear maximum and minimum values
for every item in every screen.
◎
◎
◎
Reset W
h, varh, and VAh to
zero.
All measured values are reset to zero simultaneously.
◎
Reset operating time to zero.
(The operating time displayed on the screen only)
○
Reset the alarm displayed on the
screen.
They are available
only when set to
manual alarm
cancellation.
◎
Reset all alarms at once.
(For every item in every screen)
○
Stop the backlight blinking caused by alarm only when set to
backlight blinking.
Mod
e
s
w
itc
h
◎
◎
Enter the setting mode.
◎
Enter the setting confirmation mode.
◎
◎
Enter the password protection screen.
S
e
tting
mod
e
/
S
e
tting
c
o
n
firma
tion
mod
e
S
e
tting
o
p
e
ra
tion
○
Determine the settings and then shift to the next settings.
○
Return to the previous setting item.
○
□
○
□
Round up/down the setting value.
Pressing for 1 second or more enables fast forward.
□
Skip the settings and return to the setting menu screen.
○
Reflect the setting change on the END screen.
○
Cancel the setting change on the CANCEL screen.
S
p
e
c
ial
o
p
e
ra
tion
□
□
Restart the instrument on the CANCEL screen.
◎
◎
Initialize to the factory default settings on the CANCEL
screen. Refer to
Note: During backlight off mode, pressing any operation button first turns on the backlight. In addition, pressing any button
again enables the use of the functions in the above table.
SET
-
+
RESET MAX/MIN PHASE DISPLAY
SET button RESET button Phase button
+/- button MAX/MIN button DISPLAY button