1
1
PRE-OPERATION INSTRUCTIONS
1.1
Unpacking and Product Confirmation
Take the plug-in option out of the package, check the product name, and confirm that the product is as you
ordered and intact.
This product is a plug-in option for the FR-E700 series inverter.
1.1.1 SERIAL number
Check the SERIAL number indicated on the rating plate or package.
For the 200V class of FR-E700, this option can be used with the inverter having the following SERIAL
number or later. (For the 400V class of FR-E700, this option can be used with all inverters regardless of
SERIAL number.)
z
SERIAL number check
Refer to
the Instruction Manual of the inverter
for the location of the rating plate.
Type
SERIAL number
FR-E720-0.1K to 0.75K
J7Y
{{{{{{
FR-E720-1.5K to 5.5K
K7Y
{{{{{{
FR-E720-7.5K
L7Y
{{{{{{
FR-E720-11K, 15K
G7Y
{{{{{{
Rating plate example
7
Y
{{{{{{
SERIAL (Serial No.)
Symbol Year
Month
Control number
The SERIAL consists of one symbol, two characters indicating production year and month,
and six characters indicating control number.
The last digit of the production year is indicated as the Year, and the Month is indicated by
1 to 9, X (October), Y (November), or Z (December).