![Mitsubishi Electric EZMOTION MR-E Super MR-E-10A-QW003 Instruction Manual Download Page 90](http://html.mh-extra.com/html/mitsubishi-electric/ezmotion-mr-e-super-mr-e-10a-qw003/ezmotion-mr-e-super-mr-e-10a-qw003_instruction-manual_238867090.webp)
5 - 5
5. PARAMETERS
(2) Details list
Class No. Symbol
Name and function
Initial
value
Unit
Setting
range
Control
mode
Control mode, regenerative option selection
Used to select the control mode and regenerative option.
Selection of regenerative option
0: Regenerative option is not used
For the servo amplifier of 200W or
lower, regenerative resistor is not used.
For the servo amplifier of 400W or
higher, built-in regenerative resistor is
used.
2: MR-RB032
3: MR-RB12
4: MR-RB32
5: MR-RB30
6: MR-RB50 (Cooling fan is required)
Select the control mode.
0: Position
1: Position and internal speed
2: Internal speed
Motor series selection
0: HF-KE W1-S100
1: HF-SE JW1-S100
Motor capacity selection
0: 100W
1: 200W
2: 400W
3: 500W
4: 750W
5: 1kW
6: 1.5kW
7: 2kW
POINT
Wrong setting may cause the regenerative option to burn.
If the regenerative option selected is not for use with the servo
amplifier, parameter error (AL.37) occurs.
0 *STY
100W
: 0000
200W
: 1000
400W
: 2000
750W
: 4000
1kW
: 5010
2kW
: 6010
Refer to
name
and
function
column.
P S
B
as
ic
param
et
ers
1
*OP1 Function selection 1
Used to select the input signal filter, the function of pin CN1-12.
Input signal filter
If external input signal causes chattering
due to noise, etc., input filter is used to
suppress it.
0: None
1: 1.777[ms]
2: 3.555[ms]
3: 5.333[ms]
CN1-12 function selection
0: Zero Speed detection signal
1: Electromagnetic brake interlock (MBR)
0
0
0002
Refer
to
name
and
function
column.
P S
www.DataSheet4U.com
Summary of Contents for EZMOTION MR-E Super MR-E-10A-QW003
Page 17: ...6 MEMO www DataSheet4U com ...
Page 31: ...2 4 2 INSTALLATION MEMO www DataSheet4U com ...
Page 85: ...4 6 4 OPERATION MEMO www DataSheet4U com ...
Page 115: ...5 30 5 PARAMETERS MEMO www DataSheet4U com ...
Page 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO www DataSheet4U com ...
Page 163: ...10 12 10 TROUBLESHOOTING MEMO www DataSheet4U com ...