![Mitsubishi Electric EZMOTION MR-E Super MR-E-10A-QW003 Instruction Manual Download Page 295](http://html.mh-extra.com/html/mitsubishi-electric/ezmotion-mr-e-super-mr-e-10a-qw003/ezmotion-mr-e-super-mr-e-10a-qw003_instruction-manual_238867295.webp)
15 - 36
15. MR-E- AG-QW003 SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
Class No. Symbol
Name and function
Initial
value
Unit
Setting
range
Control
mode
2 ATU
Auto
tuning
Used to selection the response level, etc. for execution of auto tuning.
Refer to chapter 7.
Auto tuning response level setting
If the machine hunts or generates
large gear sound, decrease the
set value.
To improve performance, e.g.
shorten the settling time, increase
the set value.
Set
value
Response
level
1
Low
response
Middle
response
High
response
Gain adjustment mode selection
(For more information, refer to section 7.1.1.)
Machine resonance
frequency guideline
15Hz
2
20Hz
3
25Hz
4
30Hz
5
35Hz
6
45Hz
7
55Hz
8
70Hz
9
85Hz
A
105Hz
B
130Hz
C
160Hz
D
200Hz
E
240Hz
F
300Hz
Set
value
Gain adjustment mode
0
Description
1
3
Simple manual adjustment.
4
Manual adjustment of all gains.
Interpolation mode
Fixes position control gain 1
(parameter No.6).
Auto tuning mode 1
Fixes the load inertia moment
ratio set in parameter No.34.
Response level setting can be
changed.
Manual mode 1
Manual mode 2
2
Auto tuning mode 2
Ordinary auto tuning.
0
0
0105
Refer
to
name
and
function
column.
S
3
1
4
1
5
For manufacturer setting
Do not change this value by any means.
100
6
PG1
Position loop gain 1
Used to set the gain of position loop.
Increase the gain to improve track ability in response to the position
command.
When auto turning mode 1,2 is selected, the result of auto turning is
automatically used.
To use this parameter, set "
1 " to parameter No.20 to validate servo
lock at stop.
35 S
B
as
ic
param
et
ers
7
For manufacturer setting
Do not change this value by any means.
3
www.DataSheet4U.com
Summary of Contents for EZMOTION MR-E Super MR-E-10A-QW003
Page 17: ...6 MEMO www DataSheet4U com ...
Page 31: ...2 4 2 INSTALLATION MEMO www DataSheet4U com ...
Page 85: ...4 6 4 OPERATION MEMO www DataSheet4U com ...
Page 115: ...5 30 5 PARAMETERS MEMO www DataSheet4U com ...
Page 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO www DataSheet4U com ...
Page 163: ...10 12 10 TROUBLESHOOTING MEMO www DataSheet4U com ...