![Mitsubishi Electric EZMOTION MR-E Super MR-E-10A-QW003 Instruction Manual Download Page 135](http://html.mh-extra.com/html/mitsubishi-electric/ezmotion-mr-e-super-mr-e-10a-qw003/ezmotion-mr-e-super-mr-e-10a-qw003_instruction-manual_238867135.webp)
7 - 6
7. GENERAL GAIN ADJUSTMENT
7.2.4 Response level setting in auto tuning mode
Set the response (The first digit of parameter No.2) of the whole servo system. As the response level setting is
increased, the track ability and settling time for a command decreases, but a too high response level will
generate vibration. Hence, make setting until desired response is obtained within the vibration-free range.
If the response level setting cannot be increased up to the desired response because of machine resonance
beyond 100Hz, adaptive vibration suppression control (parameter No.60) or machine resonance suppression
filter (parameter No.58 59) may be used to suppress machine resonance. Suppressing machine resonance
may allow the response level setting to increase. Refer to section 8.2, 8.3 for adaptive vibration suppression
control and machine resonance suppression filter.
Parameter No.2
Response level setting
Gain adjustment mode selection
Machine characteristic
Response level setting
Machine rigidity
Machine resonance
frequency guideline
Guideline of corresponding machine
1 Low
15Hz
2
20Hz
3
25Hz
4
30Hz
5
35Hz
6
45Hz
7
55Hz
8 Middle
70Hz
9
85Hz
A
105Hz
B
130Hz
C
160Hz
D
200Hz
E
240Hz
F High
300Hz
Large conveyor
Arm robot
General machine
tool conveyor
Precision
working
machine
Inserter
Mounter
Bonder
www.DataSheet4U.com
Summary of Contents for EZMOTION MR-E Super MR-E-10A-QW003
Page 17: ...6 MEMO www DataSheet4U com ...
Page 31: ...2 4 2 INSTALLATION MEMO www DataSheet4U com ...
Page 85: ...4 6 4 OPERATION MEMO www DataSheet4U com ...
Page 115: ...5 30 5 PARAMETERS MEMO www DataSheet4U com ...
Page 149: ...8 10 8 SPECIAL ADJUSTMENT FUNCTIONS MEMO www DataSheet4U com ...
Page 163: ...10 12 10 TROUBLESHOOTING MEMO www DataSheet4U com ...