B
NECS-ME
7 FULL LOAD SOUND LEVEL
SIZE
Octave band [Hz]
2000
1000
500
250
125
63
8000
4000
Total sound
level
Sound power level dB(A)
SOUND POWER
74
72
69
70
70
63
59
53
73
0152
75
73
70
71
71
64
60
54
74
0182
75
73
70
71
71
64
60
54
74
0202
75
73
70
71
71
64
60
54
74
0252
76
74
71
72
72
65
61
55
75
0262
76
74
75
74
70
68
64
53
76
0302
77
75
76
75
71
69
65
54
77
0352
77
75
76
75
71
69
65
54
77
0412
78
76
77
76
72
70
66
55
78
0452
78
76
77
76
72
70
66
55
78
0512
79
77
78
77
73
71
67
56
79
0552
79
77
78
77
73
71
67
56
79
0612
75
77
81
80
82
80
74
68
86
0604
76
78
82
81
83
81
75
69
87
0704
77
79
83
82
84
82
76
70
88
0804
78
80
84
83
85
83
77
71
89
0904
79
81
85
84
86
84
78
72
90
1004
80
82
86
85
87
85
79
73
91
1104
80
82
86
85
87
85
79
73
91
1204
80
82
86
85
87
85
79
73
91
1404
80
82
86
85
87
85
79
73
91
69
70
70
70
71
72
73
73
74
74
75
75
76
77
78
79
80
81
81
81
81
1604
Plant (side) cooling exchanger water (in/out) 12/7 °C
Condensation temperature 47 °C
Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units;
in compliance with ISO 3744 for non-certified units
Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.
Working conditions
SIZE
Octave band [Hz] at 10 m
2000
1000
500
250
125
63
8000
4000
Total sound
level
Sound pressure level dB(A)
SOUND PRESSURE LEVEL
43
41
38
39
39
32
28
22
42
0152
44
42
39
40
40
33
29
23
43
0182
44
42
39
40
40
33
29
23
43
0202
44
42
39
40
40
33
29
23
43
0252
45
43
40
41
41
34
30
24
44
0262
44
42
43
42
38
36
32
21
44
0302
45
43
44
43
39
37
33
22
45
0352
45
43
44
43
39
37
33
22
45
0412
46
44
45
44
40
38
34
23
46
0452
46
44
45
44
40
38
34
23
46
0512
47
45
46
45
41
39
35
24
47
0552
47
45
46
45
41
39
35
24
47
0612
43
45
49
48
50
48
42
36
54
0604
44
46
50
49
51
49
43
37
55
0704
45
47
51
50
52
50
44
38
56
0804
46
48
52
51
53
51
45
39
57
0904
47
49
53
52
54
52
46
40
58
1004
48
50
54
53
55
53
47
41
59
1104
48
50
54
53
55
53
47
41
59
1204
48
50
54
53
55
53
47
41
59
1404
48
50
54
53
55
53
47
41
59
1604
Plant (side) cooling exchanger water (in/out) 12/7 °C
Condensation temperature 47 °C
Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; non-binding value obtained
from the sound power level
Working conditions
ELCADOC - Ver. 1.0.0.1
NECS-ME_0152_1604_201004_GB
Ref.: R410A
Total sound
level
Standard unit
With insulation
cover
Standard unit