SIZE
0804
0904
1004
1104
1204
1404
1604
B
NECS-ME
GENERAL TECHNICAL DATA
COOLING
(1)
Cooling capacity
kW
207
235
263
301
339
387
432
Total power input (unit)
kW
60,6
67,9
75,2
86,5
97,8
111
124
EER
ESEER
3,42
-
3,47
-
3,50
-
3,47
-
3,47
-
3,49
-
3,48
-
Heat exchanger water flow
m³/h
35,7
40,5
45,3
51,7
58,4
66,5
74,3
Heat exchanger pressure drop
kPa
38,8
38,9
39,4
36,7
46,7
49,6
54,7
NECS-ME /B
COMPRESSORS
Number
Number of capacity
Number of circuits
N°.
N°.
N°.
4
4
4
4
4
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
2
Type of regulation
STEPS
STEPS
STEPS
STEPS
STEPS
STEPS
STEPS
6,3
6,3
6,3
6,8
6,8
4,7
4,7
kg.
Oil charge
-
-
-
-
-
-
-
kg.
Refrigerant charge
R410A
R410A
R410A
R410A
R410A
R410A
R410A
Type of refrigerant
%
25
25
25
25
25
25
25
Minimum capacity steps
NOISE LEVELS
(2)
Total sound power
dB(A)
88
89
90
91
91
91
91
59
59
58
57
56
dB(A)
Total sound pressure
59
59
DIMENSIONS AND WEIGHTS
(3)
Length
Width
Height
Weight
mm.
mm.
mm.
kg.
2227
1020
1780
1125
2227
1020
1780
1185
2227
1020
1780
1250
2227
1020
1780
1330
2227
1020
1780
1370
2227
1020
1780
1430
2227
1020
1780
1480
1
Plant (side) cooling exchanger water (in/out) 12/7 °C
Condensation temperature 47 °C
2
Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units;
in compliance with ISO 3744 for non-certified units
Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; non-binding value obtained
from the sound power level
3
Standard configuration
- Not
available
7
ELCADOC - Ver. 1.0.0.1
NECS-ME_0152_1604_201004_
*%
Ref.: R410A