OCH790 _7
3 OVERVIEW OF UNITS
3-1. System construction
Wireless remote
controller
M series indoor unit
*5, *
6
MSZ-SF·VA/VE series
MSZ-EF·VE/VG(K) series
MSZ-FH·VE series
MFZ-KJ·VE series
MFZ-KT·VG series
MFXZ-KW·VG series
MSZ-LN·VG(2) series
MSZ-AP·VG(K) series
MSZ-AP·VF series
CONNECTION KIT
PAC-LV11M-J
Model name
CMY-Y62-G-E
CMY-Y64-G-E
CMY-Y68-G-E
Number of branches
2
4
8
Outdoor unit
Horsepower
4.5 HP
5 HP
6 HP
Model name
P112
P125
P140
Applicable indoor unit
Capacity class
10 to 140
Number of units
1 to 9
1 to 10
1 to 12
Total system capacity range
50 to 130% of outdoor unit capacity
*
1
*2
Connectable indoor unit lineup
Model type
Model name
10
15
20
25
32
40
50
63
71
80
100 125 140
Cassette
ceiling
2 by 2
PLFY-P·VFM-E
●
●
●
●
●
●
2-way flow PLFY-P·VLMD-E
●
●
●
●
●
●
●
●
●
4-way flow PLFY-P·VEM-E
●
●
●
●
●
●
●
●
●
PLFY-M·VEM6-E
●
●
●
●
●
●
●
●
●
●
PLFY-M·VEM-E
●
●
●
●
●
●
●
●
●
1-way flow PMFY-P·VBM-E
●
●
●
●
Ceiling concealed
PEFY-P·VMA(L)-E/E2
●
●
●
●
●
●
●
●
●
●
●
PEFY-P·VMA(L)-E3/E4
●
●
●
●
●
●
●
●
●
●
●
PEFY-P·VMHS-E
●
●
●
●
●
●
●
●
PEFY-P·VMR-E-L/R
●
●
●
PEFY-M·VMA-A1
●
●
●
●
●
●
●
●
●
●
●
Wall mounted
PKFY-P·VLM-E
●
●
●
●
●
●
●
PKFY-P·VKM-E
●
●
Ceiling suspended
PCFY-P·VKM-E
●
●
●
●
Floor
standing
Exposed
PFFY-P·VLEM-E
●
●
●
●
●
●
PFFY-P·VKM-E
●
●
●
●
Concealed
PFFY-P·VLRM(M)-E
●
●
●
●
●
●
PFFY-P·VCM-E
●
●
●
●
●
●
Ceiling
concealed
Fresh air
*3
PEFY-P·VMHS-E-F
●
Lossnay
GUF·RD(H)4
*
4
●
●
Air to Water unit
*2
PWFY-P·VM-E1/E2-AU
●
Remote controller
Name
M-NET remote controller
MA remote controller
Model name
PAR-F27MEA-E, PAR-U02MEDA
PAR-4xMAA, PAR-3xMAA ("x" represents 0 or later)
Functions
•
A handy remote controller for use in conjunction
with the Melans centralized management system.
• Address setting is required.
• Address setting is not required.
*1. When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit
capacity is 110%.
*2.
When connecting PWFY series (Note that the connection is not allowed inside EU countries and the UK.)
Only 1 PWFY-P100VM-E-AU can be connected. PWFY-P200VM-E-AU and PWFY-P100VM-E-BU cannot be con-
nected.
The PWFY unit cannot be the only unit connected to an outdoor unit. Select an indoor unit so that the total rated
capacity of the indoor units, excluding the PWFY unit, is 50 to 100% of the outdoor unit capacity.
*3.
PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "3-4-3. Operating temperature range".
*4. Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-60DR-E, PZ-52SF-E, PZ-43SMF-E)
*5. When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual
for the CONNECTION KIT.
*6.
The CONNECTION KIT cannot be connected to the indoor unit whose model name is 60 or larger and LN 18.