5.3 VIA VT8231 BGA PCI-LPC/ISA South Bridge
General Purpose I/Os
Signal Name
PIN #
I/O
Signal Description
GPIOA
/ GPI24 /
GPO24
Y2
IO / I / O
General Purpose I/O A / 24.
(F4 RxE6[0] defines as GPI
or GPO)
GPIOB
/ IRRX2
T8
IO / I
General Purpose I/O B.
(See FIR I/O Rx33 and 34)
GPIOC
/ GPI25 /
GPO25 / ATEST
/ CHSINOUT
J5
IO / I / O / O
General Purpose I/O C / 25.
(F4 RxE6[1] defines as GPI
or GPO)
GPIOD
/ GPI30 /
GPO30 / DTEST
Y1
IO / I / O / O
General Purpose I/O D / 30.
(F4 RxE6[6] defines as GPI
or GPO)
GPIOE
/ GPI31 /
GPO31
W3 IO
General Purpose I/O E / 31.
(F4 RxE6[7] defines as GPI
or GPO)
Hardware Monitoring
Signal Name
PIN #
I/O
Signal Description
UIC1
M1 Analog
I
Universal Input Channel.
For temperature / voltage
monitoring.
UIC2
M3 Analog
I
Universal Input Channel.
For temperature / voltage
monitoring.
UIC3
M2 Analog
I
Universal Input Channel.
For temperature / voltage
monitoring.
UIC4
L4 Analog
I
Universal Input Channel.
For temperature / voltage
monitoring.
UIC5
L1 Analog
I
Universal Input Channel.
For temperature / voltage
monitoring.
DTD+
L2 Analog
I
CPU DTD (Thermal Diode) Channel Plus.
DTD-
L3 Analog
I
CPU DTD (Thermal Diode) Channel Minus.
VREF
K1 O
Voltage Reference for Thermal Sensing
(2.2V ?5%)
FAN1
K2 I
Fan Speed Monitor 1.
(3.3V only)
FAN2
/ SLPBTN# /
GPI18 / GPO18
K3 I / I / I / O
Fan Speed Monitor 2.
(3.3V only) (F4 RxE5[0] = 0)
DTEST
/ GPIOD (30)
Y1 O
Hardware Monitor Digital Test Out
ATEST
/ GPIOC (25) /
CHSINOUT
J2 O
Hardware Monitor Analog Test Out
Power Management and External State Monitoring
Signal Name
PIN #
I/O
Signal Description
PME#
/ GPI6
U1
I / I
Power Management Event.
(Rx74[1]=0) (1K PU to
VCCS if not used)
EXTSMI#
/ GPI2
W1
IOD / I
External System Management Interrupt.
When enabled
to allow it, a falling edge on this input causes an SMI# to
be generated to the CPU to enter SMI mode. (10K PU to
VCCS if not used) (3.3V only)
SMBALRT#
/ GPI7
T2
I / I
SMB Alert
(System Management Bus I/O space Rx08[3]
= 1). When the chip is enabled to allow it, assertion
generates an IRQ or SMI or power management event.
(10K PU to VCCS if not used)
THRM
/ AOLGPI /
GPI17
P3
I / I / I
Monitor Input - Thermal Alarm.
(F4 Rx40[7]=0) (1K
PU to VCCS if not used)
LID
/ GPI4
V2
I / I
Monitor Input - Notebook Computer Display Lid Open
/ Closed.
Used by the Power Management subsystem to
monitor the opening and closing of the display lid of
notebook computers. Can be used to detect either
low-to-high and/or high-to-low transitions to generate an
SMI#. The VT8231 performs a 200 usec debounce of this
input if Function 4 Rx40[5] is set to 1. (10K PU to VCCS
if not used)
RING#
/ GPI3
U3
I / I
Monitor Input – Modem Ring.
May be connected to
external modem circuitry to allow the system to be
re-activated by a received phone call. (10K PU to VCCS if
not used)
BATLOW#
/ GPI5
T3
I / I
Monitor Input - Battery Low.
(10K PU to VCCS if not
used)
CPUMISS
/ GPI16
V1
I / I
Monitor Input - CPU Missing.
Indicates whether the
CPU is plugged in correctly.
AOLGPI
/ GPI17 /
THRM
P3
I / I / I
Monitor Input - Awake On LAN External Event.
F4
Rx40[7]=1
INTRUDER#
/ GPI8
F3
I / I
Monitor Input – Chassis Intrusion.
RSMRST#
F2
I
Resume Reset.
Resets the internal logic connected to the
VCCS power plane and also resets portions of the internal
RTC logic.
SUSA#
/ GPO1 /
strap
P1
O / O / I
Suspend Plane A Control
(Function 4 Rx54[2]=0).
Asserted during power management POS, STR, and STD
suspend states. Used to control the primary power plane.
(10K PU to VCCS if not used)