34
10. Service
WATER RELATED PROBLEMS
Symptoms Experienced
Possible Problem or Cause
Solution
•
The faucet is not dispensing
hot water.
•
The faucet is not dispensing
cold water.
•
Only one water temperature
is dispensed. Not able to
change water to hot or cold.
Interruption in communication
between the motor and Cartouche
components located inside the
waterbox.
NOTE: Please check the miscea
system is connected to a hot
and cold water outlet or device
that allows for availability of hot
water. If only a cold water outlet is
available, then it is not possible to
receive hot water.
Disconnect the miscea system
from the power point. After 10 sec-
onds, reconnect the miscea system
to the power point. This should
reset the system and resolve any
minor system glitches.
If the problem persists, please
contact miscea GmbH for further
technical assistance.
The faucet is not dispensing
water.
The system is not plugged into a
working power point.
The mains water supply is not set
to open.
The shut off valve (if available) is
not set to open.
Check the system is plugged into a
working power point and switched
on.
Check the mains water supply is
set to open.
Check the shut off valve (if avail
-
able) is set to open.
Check all cable and tubing con-
nections for loose connections or
incorrect connections. Please refer
to relevant pages of the manual for
correct installation procedures.
An issue with one or more of the
components in the waterbox.
Disconnect the miscea system
from the power point. After 10 sec-
onds, reconnect the miscea system
to the power point. This should
reset the system and resolve any
minor system glitches.
If the problem persists, please
contact miscea GmbH for further
technical assistance.
The faucet is leaking/dripping
water.
If newly installed, the mains water
supply was not flushed thoroughly
enough before installation, result-
ing in dirt particles entering the
waterbox, causing problems with
components inside the waterbox.
Disconnect the miscea system
from the power point. After 10 sec-
onds, reconnect the miscea system
to the power point. This should
reset the system and resolve any
minor system glitches.
Flush the faucet using the bucket
fill mode or continuously activating
the water sector for 1 minute.
If the problem persists, please
contact miscea GmbH for further
technical assistance.
Summary of Contents for "Classic"
Page 1: ...s oap disinf e c t water Instruction manual CLASSIC EN 18 38 DE 39 60 NL 61 83 ...
Page 3: ...V 17 04 3 A B 3a 9a 5 4 6 2 3b 9b 5 4 6 2 B ...
Page 8: ...8 G01 G04 3 4 1 2 ...
Page 9: ...V 17 04 9 G H H01 H02 1 2 ...
Page 10: ...10 I01 I06 2x L 25 mm L 19 mm 1x Click 1 3 5 2 4 6 19 mm ...
Page 12: ...12 J01 J02 152 140 220 83 Ø 32 Ø 62 Ø 34 208 40 Ø 60 135 129 Ø 38 ...
Page 13: ...V 17 04 13 J01 J03 J03 124 198 48 Ø 3 8 Ø 69 ...
Page 14: ...14 J04 J05 220 77 155 280 92 220 90 ...
Page 15: ...V 17 04 15 J04 J06 J06 220 77 155 ...
Page 16: ...16 ...
Page 17: ...NL EN DE s oap disinf e c t water Instruction manual CLASSIC ...
Page 38: ...38 ...
Page 39: ...NL EN DE Betriebsanleitung CLASSIC s eife desinf e k t wasser ...
Page 61: ...NL EN DE s oap disinf e c t water Gebruikershandleiding CLASSIC ...
Page 82: ...82 ...
Page 83: ...V 17 04 83 Nederlands ...
Page 84: ...miscea GmbH Hauptstraße 2 14979 Großbeeren Germany W www miscea com E info miscea com ...