Kaleido-X16
Hardware Description & Installation Manual
53
3. Apply power to the ABT and make sure it is connected to the hub or switch.
4. Press the RESET button for at least 1 second.
The ABT will reboot with the following static network configuration:
5. Using the browser, connect to the unit using the following address: 10.0.3.190.
The Web server serves the Web pages that allow monitoring and configuration of the parameters. You
can access these pages by clicking on the links on the left side of the current page.
The individual pages are described in the following sections.
Parameter
Value
DHCP
OFF
Static IP address
10.0.0.1
Subnet mask
255.255.0.0
Default gateway
10.0.0.1
Note:
If the hub or switch is Power over Ethernet (PoE) enabled, simply connect it to the unit
using an Ethernet cable. If not, PoE mid-span (‘inserter’) equipment must be placed between the
hub or switch and the Audio Bridge Terminal.
Note:
The RESET button is beside the ETHERNET/POWER RJ-45 connector.
Parameter
Value
DHCP
OFF
Static IP address
10.0.3.190
Subnet mask
255.255.0.0
Default gateway
10.0.0.1