Kaleido-X16
Hardware Description & Installation Manual
7
Monitoring the Temperature of the Kaleido-X16 Frame
For optimal performance, it is strongly recommended that you operate the Kaleido-X16 frame in an
environment with an ambient temperature between 0ºC and 40ºC.
There are two factors that could influence airflow inside the frame: altitude and airflow obstruction on the
sides of the unit.
LED
LED Status
Green
Blinking
green
Red
Blinking red Yellow
Blinking
yellow
Off
CPU
Normal
operation
Application
booting
Error
Live Update
OS Booting
N/A
N/A
CPF
Activity
N/A
Activity
N/A
N/A
N/A
N/A
No
Activity
Video
Inputs
Inputs are locked N/A
• Inputs
unlocked, or
• no input
ERROR ON
SIGNAL
N/A
N/A
N/A
DVI Inputs
Inputs are locked N/A
• Inputs are
unlocked, or
• no input
ERROR ON
SIGNAL
N/A
N/A
N/A
LTC
LTC valid
N/A
LTC invalid
N/A
N/A
N/A
No signal
Ex. Ref.
Input
Input is locked
N/A
• Input is
unlocked, or
• no input
ERROR ON
SIGNAL
N/A
N/A
N/A
SDTI
Inputs are locked N/A
• Inputs are
unlocked, or
• no input, or
• no SDTI signal
ERROR ON
SIGNAL
N/A
N/A
N/A
General
Status
System OK
Intrusive self-
diagnostic
finished
Config Failed/
Safe Mode
FW Upgrading
Boot up
Diagnostic
(Verbose switch
on)
Firmware error
N/A
Severity
Boot OK
Booting
Boot error
Need live-
update
Fatal error
CALL TECH
SUPPORT
N/A
N/A
No power
IMPORTANT:
When measuring the ambient room temperature, take your readings from directly in front of the
Kaleido-X16 frame.
Summary of Contents for Kaleido-X16
Page 4: ......
Page 32: ...26 Kaleido X16 Installation Replacing a Defective Power Supply 1 ...
Page 80: ...74 Specifications Physical Dimensions 3 ...
Page 82: ......