background image

48

Peripheral Equipment

Description

2

ABT-128D-75 rear panel layout

 

ABT-128D-110 rear panel layout

ABT-64D-75 rear panel layout

ABT-64D-110 rear panel layout

Summary of Contents for Kaleido-X16

Page 1: ...ation Manual Part Number M869 9902 101 11 August 2009 Questions about the Kaleido X16 Telephone 1 514 333 1772 e mail techsupp miranda com Comments and Suggestions about the Kaleido X16 Documentation e mail Documentation Feedback Miranda com ...

Page 2: ... or mechanical includingphotocopyingandrecording foranypurposeunlessspecificallyauthorized in writing by Miranda Technologies Inc A Miranda Technologies Inc manual may have been revised to reflect changes made to the productduringitsmanufacturinglife Thus differentversionsofamanualmayexistforanygiven product Care should be taken to ensure that one obtains the proper manual version for a specific p...

Page 3: ...th FCC Part 15 Subpart B class A requirements for Digital Devices This equipment complies with the requirements of EN 55022 Class A Radiated Emissions EN 55022 Class A Conducted Emissions EN 61000 4 2 3 11 Electromagnetic Immunity EN 61000 3 2 3 3 Disturbance in Supply Systems Warranty Policies Warranty information is available in the Support section of the Miranda Web site http www miranda com CA...

Page 4: ......

Page 5: ...cal Installation 5 Frame 6 Power Supplies 8 Ventilation 10 CompactFlash 11 Signalling 12 Inputs 13 Video and Graphic Output over the MV Out Connection 14 External Reference 14 Router 15 Audio I O 15 Control 18 Maintenance 24 Cleaning the Air Filter 24 Replacing a Defective Power Supply 25 2 Peripheral Equipment 27 Kaleido RCP2 27 Introduction 27 Description 27 Connections 28 Control Surface Layout...

Page 6: ...puts 63 Router Outputs 65 Kaleido X16 Audio I O 67 SDTI Audio Input 67 Analog Audio Monitoring 67 AES Outputs 68 Kaleido X16 Control 68 Time Code Inputs LTC 68 GPI 68 Ethernet 69 RS 422 69 USB 69 Kaleido X16 Frame 70 Kaleido RCP2 70 Audio Bridge Terminal ABT 71 Analog Audio Inputs 71 Digital Audio Inputs 71 Processing Performance 72 Reference Input 72 SDTI Outputs 73 AES3 Output 73 AES3ID Output 7...

Page 7: ...echanical Installation 5 Frame andElectrical Installation 5 CompactFlash 11 Signalling 12 Maintenance 24 Introduction The Kaleido X16 system is a cost effective multi image processor The Kaleido X16 can accommodate smallersystemsorscaleuptoproductionsystems wheresmallerbuildingblockswithfewerinputcounts perdisplayaredesirable Eachchassiscandisplayupto16 auto sensingHD SD orAnaloginputsthatcan be d...

Page 8: ...ido X16 can behave as a router with 16 input channels as sources and the two RT OUT outputs as destinations Superior display Highest quality multi image output without compression with superior on screen graphics for the most critical live monitoring applications 128 audio channels Unprecedented audio performance with the ability to monitor up to 128 channels of audio including embedded discrete a...

Page 9: ...ss to the network The diagram below shows an individual Kaleido X16 Dual system with its inputs and outputs Examples of the various external devices that connect to the Kaleido X16 are also shown The Kaleido X16 system is available in two model types the Kaleido X16 D and the Kaleido X16 S Throughoutthismanual Kaleido X16referstobothmodelsunlessitisusedtodistinguishthesinglehead model from the dua...

Page 10: ...wo models Kaleido X16 S Thereisonehead Head 1 ontheKaleido X16 Single Kaleido X16 S TheInputandOutputconnections are as follows The rear connector panel for this model is displayed below Connection type Number of connections on Head 1 Number of connections on Head 2 MV Out 1 1 DVI In 1 1 Seealso For moreinformationaboutthe Audio I OTBApinout differencesbetweenthe two Kaleido X16 models see AudioI ...

Page 11: ...oper screws and washers not included The Kaleido RCP2 may also be installed in a rack using the optional KRCP RK2 mounting kit Frame and Electrical Installation The Kaleido X16 frame is a self contained unit consisting of a frame redundant power supplies and various input and output cards The monitor wall displays and external control devices complete the system Seealso For moreinformationaboutthe...

Page 12: ...e incorporates the following key sections A rack mountable mechanical framework for mounting into a 19 in EIA rack A removable door to cover and protect the front of the frame Redundant power supply Ventilation Front viewofthe Kaleido X16frame PSUsinstalled frontcover removed LEDs onthefrontoftheframe behind thedoor TheLEDsonthefrontoftheframe behindthedoor indicatethefollowingconditionsdependingo...

Page 13: ...eo Inputs Inputsarelocked N A Inputs unlocked or no input ERROR ON SIGNAL N A N A N A DVI Inputs Inputsarelocked N A Inputs are unlocked or no input ERROR ON SIGNAL N A N A N A LTC LTC valid N A LTC invalid N A N A N A No signal Ex Ref Input Input is locked N A Input is unlocked or no input ERROR ON SIGNAL N A N A N A SDTI Inputsarelocked N A Inputs are unlocked or no input or no SDTI signal ERROR...

Page 14: ...ving the front door of the frame Viewed from the front of the frame the PSUs are located on the left hand and right hand sides of the frame IMPORTANT If your frame has only one PSU it must be installed in Slot A left side of frame Therearetwopowersupplies anoperationalPSUandaredundantPSU Thesystemoperateswith asinglePSU IfyouchoosetohaveonlyonePSUinstalledinyourKaleido X16frame youmustdo thefollow...

Page 15: ... the PSU and pull the PSU out of the frame Installing a Power Supply To install a power supply do the following 1 Positionthepowersupply PSU infrontofanemptypowersupply slotinfrontoftheframe withthe connector end towards the frame and the PSU handle on the right side 2 Slide the PSU into the empty slot moving it gently until it contacts the sockets at the rear of the slot 3 Push firmly but gently ...

Page 16: ...ame The left power socket is for PSU B The right power socket is for PSU A Ventilation The Kaleido X16 frame is cooled by ventilation intakes located on the front of the frame Fans are located in key positions within the frame Airflow throughtheKaleido X16 frame IMPORTANT A Kaleido X16 frame candraw 4 0amps of current Ensurethat the circuit towhichthe frame is connectedcanhandlethat load andthat o...

Page 17: ...me see diagrams above and below Air Filter CoolingairdrawnintotheKaleido X16framebytheventilatingfanspassesthroughafilterlocatedbehind a grille in the front door of the frame CompactFlash In order to boot the CPU you must ensure the appropriate CompactFlash CF card is properly inserted in theCFslot accessiblefromthefrontoftheKaleido X16frame TheCFcardcontainstheoperatingsystem required for a syste...

Page 18: ...lay in place of the internally generated background Inputs 1 16 BNC HD SD SDI or composite video inputs 1 to 16 MV Out 1 2 see Video and Graphic OutputovertheMV Out Connection on page 14 Digital output no analog signal compatible with a DVI D signal REF BNC Reference signal to genlock the Kaleido KX to the local plant Supported Reference formats SMPTE 170M SMPTE 318M ITU 624 4 BUT 470 6 PAL and NT...

Page 19: ...io from an external audio box Audio Bridge Terminal ETHERNET RJ 45 100 Base T Ethernet connection USB USB Connectamouse keyboard orUSBflashmemoryforsoftwareupgradeor data backup Note TherearethreeUSBports oneonthefrontoftheframe behindthe front cover and two on the rear connector panel RS 422 RJ 45 see note below Connect to an RS 422 SMPTE 207M EBU 3245 or RS 485 device or network Note The two DVI...

Page 20: ...00 at 60Hz The connectionisbasedonTMDStechnologyasusedtointerconnectindustrialandconsumerdisplays Single link DVI D cables and cables electrically compatible to this are supported Since there are two user assignable Outputs already available on the system the Outputs can be paired with the AES and Analog Output External Reference The external reference or REF input signal allows the Kaleido X16 to...

Page 21: ...standard and analogaudiomonitoring In addition the Kaleido X16 supports audio monitoring through the SDTI In port from an audio bridge terminal ABT AudioI O TBA To facilitate cabling of the audio inputs and outputs through the HD 26 connector a terminal block adapter TBA is available separately Miranda item NSH26M Seealso For moreinformationabout RouterOutputspecifications see RouterOutputs onpage...

Page 22: ...whether you have a Kaleido X16 Dual model or Kaleido X16 model Audio I OTBA Pinout onthe Kaleido X16 D The Audio I O TBA pinout on the Kaleido X16 D is as follows Bottom row Center row Top row 19 GND 10 AES Out 1 1 AES Out 1 20 GND 11 AES Out 2 2 AES Out 2 21 GND 12 GND 3 GND 22 GND 13 Analog Left Out 1 4 Analog Left Out 1 23 GND 14 Analog Right Out 1 5 Analog Right Out 1 Audio I O Terminal Block ...

Page 23: ...4 GND 15 NC 6 NC 25 GND 16 NC 7 NC 26 GND 17 PC In 1 Left 8 PC In 1 Right 18 NC 9 NC Seealso For moreinformationabout SDTI Inaudiospecifications see SDTIAudioInput onpage67 analog audio specifications see AnalogAudio Monitoring on page67 AESoutput specifications see AESOutputs onpage68 triggeringaudiomonitoring see TriggeringAudioMonitoring inthe OperationoftheMonitor Wall chapterof the Kaleido X ...

Page 24: ... 44 female on the connector panel male on the cable The pin numbering scheme for the GPI I O connector is represented in the following diagram There are 44 GPI connector pins 40 not including GND whose functions are as follows 4 Ground GND pins 32 GPI Input pins 4 GPI Output Emitter pins designated in the table below as N 4 GPI Output Collector pins designated in the table below as P The exact pin...

Page 25: ...P 3 33 GPI Output N 3 18 GPI Output P 4 3 GPI Output N 4 34 GPI Input 31 19 GPI Input 32 4 GPI Input 29 35 GND 20 GPI Input 30 5 GPI Input 27 36 GPI Input 26 21 GPI Input 28 6 GPI Input 24 37 GPI Input 23 22 GPI Input 25 7 GPI Input 21 38 GPI Input 20 23 GPI Input 22 8 GPI Input 18 39 GPI Input 16 24 GPI Input 19 9 GPI Input 15 40 GPI Input 14 25 GPI Input 17 10 GPI Input 12 41 GND 26 GPI Input 13...

Page 26: ... accommodates up to 44 terminal block connections using positive and negative terminal connections Each column on the terminal block has 6 positive and 6 negative terminal connections that correspond to each pin position Negative pins labelledwithan N ontheTerminalBlockAdapterarenotusedasconnections Positivepins labelledwith a P and Ground pins labelled with a GND correspond to GPI IN connections ...

Page 27: ...Kaleido X16 Hardware Description Installation Manual 21 Kaleido X16GPITerminalBlockAdapterinstalledin rearconnectorpanel Kaleido X16GPITerminalBlockAdapterpinout GPI Terminal Block Adapter ...

Page 28: ...e diagram at the beginningofthesectioncalled Control onpage 18 andoneisonthefrontoftheframebehindthefront cover Seealso For moreinformationabout GPI specifications see GPI on page68 triggeringGPIoutput events see TriggeringGPIOutput Events inthe Operation oftheMonitor Wall chapterof the Kaleido X User sManual calibratingGPI lines see Calibrating GPILines inthe Calibrating the Kaleido X chapter oft...

Page 29: ...or pane RS 422 The Kaleido X16 supports two RS 422 serial inputs over RJ 45 connectors These inputs allow the Kaleido X16toconnecttoexternalserialdevicessuchasarouter productionswitcher orroutercontroller Seealso For moreinformationaboutUSBspecifications see USB onpage69 USB 1 connector on front of Kaleido X16 Two USB connectors ...

Page 30: ...S 422 interface specifies a DE 9S connector so if you are using this interface you will require a DE 9S to RJ 45 adapter cable Miranda supplies such a cable correctly wired for this application Miranda part no 1737 3000 102 Note The two RS 422 ports on the Kaleido X16 side have no ground pin Using the DE 9S to RJ 45 adapter an external device should be able to communicate with a Kaleido X16 despit...

Page 31: ... the outer side of it 5 Reinstall the cover onto the frame Replacing a Defective Power Supply In the event of a power supply failure the unit will switch to the redundant power supply for its power source If a PSU s LED is not green you must replace the unit IMPORTANT Risk of damage to CompactFlash card Becareful nottodamage the CompactFlashcard asyouremovethefrontcoveroftheframe Lift thecover dir...

Page 32: ...26 Kaleido X16 Installation Replacing a Defective Power Supply 1 ...

Page 33: ...aleido X16 systems Ethernet connectivity allows multiple RCP2 users to access multiple Kaleido X16 systems allowing convenient access to the real time operating features of the Kaleido X16 Description TheKaleido RCP2isacompact freestandingcontroller Alloperatingcontrolsarelocatedonthetopofthe unit ItrequiresonlyasingleEthernetcableforbothconnectivityandpower ItalsoprovidestwoUSBports allowing a US...

Page 34: ...powered devices Two kinds of power sources are supported midspan power source injector into an existing Ethernet network and power sourcing Ethernet switch Full redundancy is obtained with both supplies present at the same time Ethernet connectivity is 10 100 Mbps 2 USB Ports These ports are used to connect a mouse and keyboard which may be used in operating the Kaleido X16 Note Multi function key...

Page 35: ...t in functional groups Layout Presets The ten numbered keys laid outacross the top ofthe panel are used to recallsaved layouts to the Kaleido X16 display and are also used to save layouts Note Other USB devices e g memory sticks are not supported USBports LayoutPresets Functions Audio Keypad Display Operatingkeys ...

Page 36: ...ing modes or functions on the Kaleido X16 Audio Keypad The keypad buttons have double functions Use the MOUSE LOCK button top left to switch between the two modes CHANNEL FULL SCREEN ALARM INHIBIT ASPECT RATIO SAFE AREA UNDERSCAN LOAD SAVE UNLATCH STATUS Note The exact functionality of these buttons is determined by the configuration of the Kaleido X16 UP ARROW Increase the audio monitoring volume...

Page 37: ...ton and the mouse function keys are bright Numeric key Mouse equivalent function 2 Pointer up 8 Pointer down 4 Pointer left 6 Pointer right 7 Click 9 Right click DISPLAY The LCD display shows messages and text entries LOGIN Log on to a Kaleido X16 through the Ethernet interface ESC Menu navigation ENTER Menu navigation PANEL ENABLE Enable disable all other keys on this control panel to prevent acc...

Page 38: ...th the appropriate unicast IP addresses see Configuring Unicast IP Addresses on page 37 Room Selection Before you can use your Kaleido RCP2 to operate a Kaleido X16 you must select the room in which to operate Use the Configuration menu to access the list of available rooms and select the one you wish to control See Selecting a Position and Logging On on page 44 for details Navigating the Configur...

Page 39: ...ogin positions that are available for this room only In the example described below the three rooms that are available are listed in this sequence RMA RMB RMC We will select room RMC 2 Move UP 8 Move DOWN ENTER Access the submenu or select the displayed value ESC Go back to the previous menu level or cancel a value selection Note These keys are lit when menu access is enabled Displaythefirmwarever...

Page 40: ...and the ENTER and ESC buttons are lit other digit keys are dimmed Press ENTER again to obtain the list of rooms from all Kaleido systems currently available on the network For some time until the list is received Acquiring room list Once the room list is received ROOM Select RMA Pressthe8keytwice untilthe room you wish to select i e RMC appears on the display Press 2to scroll in the opposite direc...

Page 41: ... seconds to access the Configuration menu At the end of the 8 seconds Configuration ROOM SELECTION Digitkeys2 UP and8 DOWN andthe ENTER and ESC buttons are lit other digit keys are dimmed Press 8 once to go to the ETHERNET OPTIONS submenu Configuration ETHERNET OPTION Press ENTER to open the Ethernet parameter menu ETHERNET OPTIONS DHCP Press ENTER again to see the current DHCP status DHCP ENABLE ...

Page 42: ...ext option in the menu Press2toreturntotheprevious option ETHERNET OPTIONS IP ADDRESS Press ENTER again toselect this option and display the current IP address You can move the cursor to the next digit position by pressing the space key UsetheDELkeytomovethecursorback to the previous position IP ADDRESS 010 000 003 191 Thecursorblinks alternatingbetweena black square and the digit All digit keys a...

Page 43: ...t IP ADDR then press ENTER 6 Usingthenumerickeypad typetheIPaddressofaKaleido X16onaremotesubnet thenpressENTER 7 Repeat step 4 to 6 to add unicast IP addresses for up to three remote Kaleido X16 systems Restoring Default Parameters The Kaleido RCP2 s Configuration menu provides an option to restore the device s default parameters This option is called FACTORY DEFAULT Selecting this option will re...

Page 44: ...icated in the Kaleido X16 Release Notes under Software and Firmware The Kaleido RCP2 firmware can be updated over the Ethernet connection Action LCD indication Other Buttons PressandholdtheENTERkeyforatleast 8 seconds to access the Configuration menu At the end of the 8 seconds Configuration ROOM SELECTION Digitkeys2 UP and8 DOWN andthe ENTER and ESC buttons are lit other digit keys are dimmed Pre...

Page 45: ...unch the Kaleido RCP2 Updater Installer and follow the on screen instructions as shown below REQUIREMENTS Make sure you fulfill the following conditions before beginning this procedure There is a PC connected to the same subnetwork as your Kaleido RCP2 unit A copy of the Kaleido RCP2 firmware update file on the PC ...

Page 46: ...the Kaleido RCP2 Firmware 2 2 Once the updater has been installed launch it The Kaleido RCP2 Updater window includes step by step instructions The initial window is shown here Note The upgrade may take as long as 15 minutes to complete ...

Page 47: ...ely click Browse to locate the appropriate file Once you have specified the firmware data file the Firmware selection zone will look like this 2 Click Next when you are done The next window includes step by step instructions for uploading the data file to the Kaleido RCP2 REQUIREMENT Make surethe Kaleido RCP2 you wish to update is on the same network as your PC Note PleasecontactMirandaTechnicalSu...

Page 48: ... room list is available press 8 repeatedly until System Updater appears on the LCD display press 2 to move back if necessary and then press ENTER 4 Press the LOGIN button twice and then wait until the position data is downloaded to the RCP2 5 Once the position data is available select the position UpdateNow then press ENTER The RCP2 prompts you for a password 6 Type 6472632 i e Miranda then press ...

Page 49: ...leido RCP2 Updater window on the PC The final screen includes instructions for verifying that the new firmware is installed and functional Note If a network problem occurs and the RCP2 stops downloading the firmware go back to step 5 Note It takes several minutes to transfer the new firmware data to the main memory IMPORTANT DonotdisconnecttheKaleido RCP2 while itisupdatingits firmware as this may...

Page 50: ...ess to the Kaleido X16 system Press the LOGIN key and select the appropriate position that corresponds to the type of user you are You may require a password to log on A room is supposed to be already set through the configuration menu of the device Here is a graphical summary of the login menu as it appears on the RCP2 s LCD display Thefollowingtableshowshowtochangetheloginposition Asan example t...

Page 51: ...ble Lit depending on the Kaleido system s configuration If the Kaleido system is not active the following message displays for 3 seconds Target system is offline Dimmed depending on the Kaleido system s configuration Press8repeatedlyto scroll the list until you reach the positionyouwishto log on to andthenpressENTERto select the new position Enter password Digit buttons are lit as well as the ENTE...

Page 52: ...ABT supports 64 channels and the 128 ABT supports 128 channels The SDTI is a BNC connection located on the rear connector panel of the frame ThereisnotenoughspaceontheKaleido X16rearpaneltoalsoincludediscreteaudioconnectors AnABT provides connector space for multiple audio signal inputs and multiplexes all the audio signals into a combined serial feed on a coaxial cable that connects to the rear c...

Page 53: ...ll connections are from the rear AudioBridgeTerminal rearview There are 6 different models of the ABT based on signal connector type and capacity Model designation Characteristics ABT 128D 110 128 digital 64 AES inputs onWECO connectors balanced 110 impedance ABT 64D 110 64 digital 32 AES inputs onWECO connectors balanced 110 impedance ABT 128D 75 128 digital 64 AES inputs onBNC connectors unbalan...

Page 54: ...48 Peripheral Equipment Description 2 ABT 128D 75rear panel layout ABT 128D 110rear panel layout ABT 64D 75rearpanel layout ABT 64D 110rear panel layout ...

Page 55: ...e of the REFERENCE SIGNAL connectors If the loop through is not used a 75 ohm termination on the other REFERENCE SIGNAL connector must be used to properly terminate the line For an Audio Bridge Terminal with an AES breakout panel AES INPUT 1 can also be used for synchronization Thisinputsignalmustbeerror freePCMaudiosampledat 48 kHz Inthecasewhereboth REFERENCESIGNALandAESINPUT 1havevalidreference...

Page 56: ... power sources are supported midspan power source injector into an existing Ethernet network power sourcing Ethernet switch Full redundancy is obtained with both supplies present at the same time Indicators TheACTIVITYindicatorislocatedontheright handsideoftherearpanel ThisLEDreportsthestatusofthe Ethernet connection as follows FrontpanelLEDS TwoLEDsarevisibleonthefrontpanel oneforeachpowersupply ...

Page 57: ...EFERENCE SIGNAL connectors If the loop through is not used a 75 ohm termination on the other REFERENCE SIGNAL connector must be used to properly terminate the line For an Audio Bridge Terminal with an AES breakout panel AES INPUT 1 can also be used for synchronization Thisinputsignalmustbeerror freePCMaudiosampledat 48 kHz Inthecasewhereboth REFERENCESIGNALandAESINPUT 1havevalidreferences thesigna...

Page 58: ...rocessed satisfactorily The validity user and channel status bits are transmitted alongside the PCM samples The input error status detected by the digital input receiver can be monitored by the Web page interface The non PCM data will pass unchanged Web Interface To access the Web interface the ABT must be connected to a local area network LAN If the unit s IP address is known you can access the b...

Page 59: ...s these pages by clicking on the links on the left side of the current page The individual pages are described in the following sections Parameter Value DHCP OFF Static IP address 10 0 0 1 Subnet mask 255 255 0 0 Defaultgateway 10 0 0 1 Note If the hub or switch is Power over Ethernet PoE enabled simply connect it to the unit usinganEthernetcable Ifnot PoEmid span inserter equipmentmustbeplacedbet...

Page 60: ...54 Peripheral Equipment Web Interface 2 Status WebPage ABT 128A StatusWebpage ABT 128D Status Webpage The Status Web page reports the status of several aspects of the ABT unit ...

Page 61: ...rInputStatusvariesdependingonthemodelofABTbeingmonitored Thenumberof inputs varies with the model In addition analog and digital inputs are reported differently Text Text color LED color OK Green Green Warning Orange Orange Hardware Error Red Red Upgrading Bold Red Flashing Red Text Text color Interpretation Freerun Orange No reference present format name Normal Video Audio NTSC HD 1080 30p AES75 ...

Page 62: ...t Status Text Color OK1 1 Silence is reported as OK in this context Normal Overload Red Digital Input Status Text Color OK Green Validity CRCC errors Yellow Parity Biphase errors Orange No lock Red Digital Input Channel Text Color OK Normal Overload Red ...

Page 63: ...he Parameters Web page allows the configuration of different parameters The ToneparameteractivatesordeactivatestheEBUtesttoneappliedsimultaneouslytoallchannels The odd channel will be a 1 kHz sine wave at 18 dBFS with a period of silence lasting 250 ms every 3 seconds The even channel will be a continuous 1 kHz sine wave at 18 dBFS ...

Page 64: ...areaddressattributedtoeachAudioBridgeTerminalunit Eachunit has a different address this being the only way to distinguish the units from each other when connected to a network The Label parameter gives the unit a label The label is found in the title of the Web page It can contain up to 16 characters Valid characters are from the English alphabet lowercase athrough z uppercase Athrough Z numbers 0...

Page 65: ...parametersonthispagecanbedisplayedbyclickingFactoryDefaults ThedefaultLabeliscomprisedoftheABTtype numberofchannelsandtheletterAforanaloginputsorD forAESinputs followedbythelastpartofitsserialnumber Thedefaultnetworkconfigurationisthesame astheoneobtainedbypressingtheRESETbuttonneartheETHERNET POWERRJ 45connector ClickCancel Changes to return to the values displayed when the page was loaded Click ...

Page 66: ...ludingtheMIUutility isprovidedontheKaleido X16DVD or can be obtained by contacting Miranda Technical Support To determine if you need to update your ABT check its firmware version see Information Web Page on page 60 and compare it with the version of the firmware update file see the Software and Firmware section in the Kaleido X16 Release Notes The firmware of the ABT can be updated over its Ether...

Page 67: ... AudioI O 67 Kaleido X16 Control 68 Kaleido X16 Frame 70 Kaleido RCP2 70 AudioBridge Terminal ABT 71 Kaleido X16 Inputs Video Signal Inputs The Kaleido X16 frame supports 16 signal inputs The supported input types include Composite SD SDI or HD SDI auto detected The processing delay is two fields if the video inputs are genlocked Signal inputs require BNC connectors ...

Page 68: ... 2 2 SMPTE 259M C 270 Mbps FORMATS 525 and 625 AUDIO SMPTE 274M 1994 CABLE LENGTH 225 m 738 ft Belden 8281 RETURN LOSS 15 dB up to 270 MHz HD SDI Inputs SIGNAL 4 2 2 SMPTE 292M C 1 5 Gbps FORMATS 720p 29 97 Hz 720p 25 Hz 720p 24 Hz 720p 59 94 Hz 720p 50 Hz 1080i 59 94 Hz 29 97PsF 1080p 29 97 Hz 1080i 50 Hz 25PsF 1080p 25 Hz 1080p 23 98 Hz 24 Hz 1080p 23 98PsF 24PsF 1080i 50 Hz ...

Page 69: ...SMPTE 299M CABLE LENGTH 100 m 328 ft Belden 1694 RETURN LOSS 15 dB up to 1 5 GHz 3Gbps Inputs SIGNAL 4 2 2 SMPTE 424M 2006 2 97 1 001 Gbps FORMATS 1920 1080p 60 Hz 1920 1080p 59 94 Hz 1920 1080p 50 Hz AUDIO SMPTE 299M CABLE LENGTH 100 m 328 ft Belden 1694 RETURN LOSS 15 dB up to 1 5 GHz 10 dB up to 2 97 GHz SIGNAL DVI D single link RESOLUTION From 800 600 to 1920 1200 NI H FREQUENCY 37 kHz to 96 k...

Page 70: ...PES Single link DVI D cables and cables electrically compatible to this Note Users can customize their own timing rates through the XEdit software for resolutions ranging from 800 600 up to 1920 1200 pixels Resolution Format name Refresh rate Hz 800 600 SVGA 50 00 800 600 SVGA 59 94 1024 768 XGA 50 00 1024 768 XGA 59 94 1280 720 50 Margay 50 00 1280 720 60 Margay 59 94 1280 768 WXGA 50 00 1280 768...

Page 71: ...UXGA 50 00 1600 1200 UXGA 59 94 1920 1080 50 Baycat 50 00 1920 1080 60 Baycat 59 94 1920 1200 UXGA 50 00 SD SDI Outputs SIGNAL 4 2 2 SMPTE 259M C 270 Mbps SMPTE 272M 1994 FORMATS 525 and 625 CABLE LENGTH 225 m 738 ft Belden 8281 RETURN LOSS 15 dB up to 270 MHz ADDITIVE JITTER 0 2 UI 100 kHz CONNECTOR TYPE BNC HD SDI Outputs SIGNAL 4 2 2 SMPTE 292M C 1 5 Gbps Resolution Format name Refresh rate Hz ...

Page 72: ...Hz CABLE LENGTH 100 m 328 ft Belden 1694 RETURN LOSS 15 dB up to 1 5 GHz ADDITIVE JITTER 0 2 UI 100 kHz CONNECTOR BNC 3Gbps Outputs SIGNAL 4 2 2 SMPTE 424M 2006 2 97 Gbps 2 97 1 001 Gbps FORMATS 1920 1080p 60 Hz 1920 1080p 59 94 Hz 1920 1080p 50 Hz CABLE LENGTH 100 m 328 ft Belden 1694 RETURN LOSS 15 dB up to 1 5 GHz 10 dB up to 2 97 GHz ADDITIVE JITTER 0 3 UI CONNECTORS BNC ...

Page 73: ...nalog audio inputs through one HD 26 connector SIGNAL SMPTE 305 up to 128 channels 64 AES CABLE LENGTH 250 m 820 ft Belden 8281 CONNECTOR BNC Analog audio input IMPEDANCE 16 000 QUANTIZATION 20 bits SAMPLING RATE 48 kHz free run MAX LEVEL 2 V p p CONNECTOR HD 26 Analog audio output SIGNAL Balanced analog audio LEVEL MAX 24 dBU QUANTIZATION 20 24 bits IMPEDANCE 600 THD N 80 dB SNR 92 dB CONNECTOR H...

Page 74: ... a bidirectional GPI interface 72 GPI software configured There are three DB 50 female connectors SIGNAL SMPTE 276M FORMAT AES 3 IMPEDANCE 110 CONNECTOR HD 26 VOLUME CONTROL Available in a future release SIGNAL SMPTE 12M 1995 EBU 3259 E ELECTRICAL LEVEL 0 3 to 5 V p p IMPEDANCE High Impedance 10k CONNECTOR BNC GPI INPUT up to 32 DESCRIPTION Contact closure SIGNAL 5 to 12 VDC FORMATS Fixed Not bidi...

Page 75: ...ntact closure SIGNAL Open collector 5 to 12 VDC MAXIMUM VOLTAGE 12 V MAXIMUM CURRENT AT 12V 70 mA FORMATS Fixed Not bidirectional PULSE MINIMUM DURATION 100 ms CONNECTOR DB 44 SIGNAL 10 100 BASE T IEEE 802 3 CONNECTOR RJ 45 SIGNAL RS 422 SMPTE 207M EBU 3245 CONNECTOR RJ 45 SIGNAL USB Version 1 0 CONNECTOR USB ...

Page 76: ...OWER 300 W DIMENSIONS H 45 mm 1 75 in 1 RU W 451 mm 18 04 in mounting flange for standard 19 inch rack D with cover and connectors 641 mm 25 25 in D without cover and connectors 591 mm 23 25 in FULL SPEC TEMPERATURE RANGE 0 40 C ambient WEIGHT 2 PSUs 10 44 kg 23 lbs WEIGHT 1 PSU 9 48 kg 21 lbs ETHERNET PORT SIGNAL 100 10 BASE T IEEE 802 3AF CONNECTOR RJ 45 with LED and 48 V power USB PORTS SIGNAL ...

Page 77: ...ONS 78 mm 203 mm 32 mm 3 5 in 8 in 1 in VOLTAGE 48 V POWER 5 W Max for RCP2 itself 5W Max for USB Devices SIGNAL 20 k balanced 10 k unbalanced MAXIMUM LEVEL 24 dBu CONNECTORS WECO AES3 LEVEL 0 2 to 7 V TERMINATION 110 balanced QUANTIZATION Up to 24 bits CONNECTORS WECO AES 3ID LEVEL 0 2 to 2 V RETURN LOSS 15 dB QUANTIZATION Up to 24 bits TERMINATION 75 unbalanced CONNECTORS BNC Ω Ω Ω Ω ...

Page 78: ...T 128 A 86 5 dB 20 to 997 Hz 82 dB 7 kHz THD n ABT 128 D 138 dB 20 Hz to 24 kHz 0 DBFS 24 dBu adjustable to 7 dBu with 1 dB steps FREQUENCY RESPONSE 20 Hz to 24 kHz 0 2 dB CMRR 38 dB 60 Hz 38 dB 20 kHz TEST TONE GENERATOR 18 dBFs 24 bit 1 KHz sine wave interrupted on left channel on every pair 250 ms 3 s EBU R49 SIGNAL 1 SMPTE 170M ITU 624 4 composite sync SMPTE 274M SMPTE 296M tri level sync AES3...

Page 79: ...ut Miscellaneous Physical Dimensions SIGNAL 2 SMPTE 305 2M CONNECTORS BNC OUTPUT LEVEL 2 7 p p OUTPUT LEVEL 2 7 p p COMMUNICATION PORT 10BASE T IEEE 802 3i 100BASE T IEEE 803 2u POWER 4 to 10 W depending on model Power over Ethernet IEEE 802 3af CONNECTOR RJ 45 HEIGHT 3 RU DEPTH 145 mm 5 71 in ...

Page 80: ...74 Specifications Physical Dimensions 3 ...

Page 81: ... m 9 00 p m EST Telephone 1 800 224 7882 Fax 1 514 335 1614 E mail techsupp miranda com Europe Middle East Africa UK Office hours 9 00 a m 6 00 p m GMT Telephone 44 0 1491 820222 Fax 44 0 1491 820002 E mail eurotech miranda com France Office hours 9 00 a m 5 00 p m GMT 1 Telephone 33 1 55 86 87 88 Fax 33 1 55 86 00 29 E mail eurotech miranda com Asia Office hours 9 00 a m 5 00 p m GMT 8 Telephone ...

Page 82: ......

Reviews: