GUIDE TO INSTALLATION AND OPERATION
IRD-3811 |
41
•
Remote System Administration – opens the Joining Locators data box,
which lists remote lookup services to which this IRD-3811 is registered.
Add:
Force the iControl service for this IRD-3811 to register itself on a
user-specified Jini lookup service, using the following syntax in the data
box:
jini://<ip_address>
where <ïp_address> is the ip address of the server running the
lookup service, e.g.:
Remove:
select one of the services listed in the window by clicking on it, and click
Remove
to open a query
box allowing you to delete it from the window.
3.4.19.2 Message Console tab
The Message Console provides a log of various status
messages generated on-board the card.
•
Newest messages appear at the bottom of the list
•
Use the scroll bar to view the entire list
Click the
Clear Messages
button to empty the message
window.
This panel is primarily provided for diagnosis purposes.
Hardware and transport stream error messages are sent to
this panel, along with card activity status reports.
Reset Card…:
Use this button to reset the card.
For various reasons, some CAM cards may stop
decrypting, stop passing the stream or even freeze.
When that happens, the only way to recover is to reset
the CAM. This involves putting it through a power
off/power on cycle. This can be done by physically
removing it from its slot and then reinserting it.
Alternatively, resetting the IRD-3811 will also reset the
CAM, and this can be done remotely via this iControl
panel
Figure 3.49 Joining Locators
Figure 3.50 Message Console