3 Operation
3.1 Control options
The IRD-3811 can be controlled in two different ways:
•
The local control panel and its push-buttons can be used to move through a menu of parameters and to adjust
parameter values (see section 3.3).
•
Miranda’s iControl system can be used to access the card’s operating parameters from a remote computer, using
a convenient graphical user interface (GUI). (see section 3.4)
3.2 Card-Edge Status LED
The status monitor LED is located on the front card-edge of the IRD-3811, and is visible through the front access door
of the DENSITÉ frame. The chart shows how the various error conditions that can be flagged on the IRD-3811 affect
the LED status.
•
If a cell in the chart is gray, the error condition cannot cause the LED to assume that status
•
If more than one LED status is possible for a particular error condition, the status is configurable.
See Section 3.4.18 for details.
•
The factory default status is shown by a
, and forced status by an
X
The LED will always show the most severe detected error status that it is configured to display, and in the chart error
severity increases from left to right, with green representing no error/disabled, and flashing red the most severe error.
Alarm Name/Error Report
Led Color
Description
Green
Yellow
Red
Flashing
Red
Card booting
X
After power-up, the led becomes yellow until Linux
is properly booted (takes about 40s)
Hardware/System Failure
X
Major hardware or system failure. In some cases,
the error log will show the reason
No Rear Detect
X
As per densité
No TS Input Signal
No MPEG TS input detected
TS Limit
TS has more than 128 PIDs or more than 64
programs or more than 1024 tables
No Video Signal
The MPEG TS input might be present, but no video
signal is available for decode
No Audio Signal
The video may be present, but no audio stream is
valid for decode
No Reference Signal
No reference signal is detected
Reference Mismatch
A reference mismatch is detected
Program not synchronized
The decoded video is not synced on PCRs
Test Bars ON
X
The card is in test mode with color bar activated
If the LED is Flashing Yellow, it means that the card is selected for local control using the Densité frame’s control
panel. See Section 3.3 for details.